        Three-dimensional multimodal medical imaging system based on freehand ultrasound and structured light

        Fecha
        2021-05-21
        Registro en:
        Jhacson Meza, Sonia H. Contreras-Ortiz, Lenny A. Romero Perez, and Andrés G. Marrugo "Three-dimensional multimodal medical imaging system based on freehand ultrasound and structured light," Optical Engineering 60(5), 054106 (21 May 2021). ttps://doi.org/10.1117/1.OE.60.5.054106
        https://hdl.handle.net/20.500.12585/10356
        10.1117/1.OE.60.5.054106
        Universidad Tecnológica de Bolívar
        Repositorio Universidad Tecnológica de Bolívar
        Autor
        Meza, Jhacson
        Contreras Ortiz, Sonia Helena
        Romero, Lenny A
        Marrugo Hernández, Andrés Guillermo
        Institución
        • Universidad Tecnológica de Bolivar UTB (Colombia)
        Resumen
        We propose a three-dimensional (3D) multimodal medical imaging system that combines freehand ultrasound and structured light 3D reconstruction in a single coordinate system without requiring registration. To the best of our knowledge, these techniques have not been combined as a multimodal imaging technique. The system complements the internal 3D information acquired with ultrasound with the external surface measured with the structured light technique. Moreover, the ultrasound probe’s optical tracking for pose estimation was implemented based on a convolutional neural network. Experimental results show the system’s high accuracy and reproducibility, as well as its potential for preoperative and intraoperative applications. The experimental multimodal error, or the distance from two surfaces obtained with different modalities, was 0.12 mm
        Materias

        Mostrar el registro completo del ítem


        Red de Repositorios Latinoamericanos
        + de 8.000.000 publicaciones disponibles
        500 instituciones participantes
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Ingreso Administradores
        Colecciones destacadas
        • Tesis latinoamericanas
        • Tesis argentinas
        • Tesis chilenas
        • Tesis peruanas
        Nuevas incorporaciones
        • Argentina
        • Brasil
        • Colombia
        • México
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Red de Repositorios Latinoamericanos | 2006-2018
         

        EXPLORAR POR

        Instituciones
        Fecha2011 - 20202001 - 20101951 - 20001901 - 19501800 - 1900

        Explorar en Red de Repositorios

        Países >
        Tipo de documento >
        Fecha de publicación >
        Instituciones >

        Red de Repositorios Latinoamericanos
        + de 8.000.000 publicaciones disponibles
        500 instituciones participantes
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Ingreso Administradores
        Colecciones destacadas
        • Tesis latinoamericanas
        • Tesis argentinas
        • Tesis chilenas
        • Tesis peruanas
        Nuevas incorporaciones
        • Argentina
        • Brasil
        • Colombia
        • México
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Red de Repositorios Latinoamericanos | 2006-2018