dc.contributorBarreto, Walter
dc.creatorOrtiz, Edwin
dc.date.accessioned2021-02-03T16:41:25Z
dc.date.available2021-02-03T16:41:25Z
dc.date.created2021-02-03T16:41:25Z
dc.date.issued2021-01-25
dc.identifierOrtiz, E. (2021). Estudio patológico del edificio Centum Business Building ubicado en el barrio la Castellana en la ciudad de Bogotá D.C. [Tesis de especialización, Especialización en Patología de la Construcción] Universidad Santo Tomás, Colombia.
dc.identifierhttp://hdl.handle.net/11634/31876
dc.identifierreponame:Repositorio Institucional Universidad Santo Tomás
dc.identifierinstname:Universidad Santo Tomás
dc.identifierrepourl:https://repository.usta.edu.co
dc.description.abstractThe following pathology study is directed to a building for office use called Centum Business Building, located in the city of Bogotá, locality No. 12 of Barrios Unidos. The building has 3 basements and 20 stories high, with an approximate construction area of ​​27,200 m2 on a 2,084m2 lot, the structure of the building is conventional type in reinforced concrete with spans between columns no greater than 10m in length. The patient presents pathological symptoms in the basement areas, with affectations in plates and screen walls (barretes). The patient presents chemical, mechanical, physical and biological affectations, which compromise the integrity of the structural elements in the basement areas, for which a detailed on-site inspection was carried out on each element to determine its degree of affectation. Elements such as bars affected by collapse, compromise the stability of the structure, as they are elements that receive and transmit the loads of the building to the foundation, elements such as screen walls that present effects such as section reduction and filtration problems can generate failure, as the bearing capacity is reduced.
dc.languagespa
dc.publisherUniversidad Santo Tomás
dc.publisherEspecialización Patología de la Construcción
dc.publisherFacultad de Ciencias y Tecnologías
dc.relationwww.corrosion-doctors.org/Concrete/Nature.htm
dc.relationSánchez de Guzmán, Durabilidad y Patología del Concreto
dc.relationGEHO-CEB, Durabilidad de Estructuras de Hormigón
dc.relationSistemas de reparación/ Ing. Nancy Torres C.
dc.relationhttps://www.google.es/maps
dc.relationReglamento Colombiano de Construcción Sismo-Resistente 2010
dc.relationResolución 600 de 2018 Lineamiento Técnico para excavaciones en Bogotá
dc.relationwww.Ingeominas.com
dc.relationwww.Idiger.com
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightsAbierto (Texto Completo)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.titleEstudio patológico del edificio Centum Business Building ubicado en el barrio la Castellana en la ciudad de Bogotá D.C.