| dc.contributor | Barbassa, Ademir Paceli | |
| dc.contributor | http://lattes.cnpq.br/2979012440240781 | |
| dc.contributor | http://lattes.cnpq.br/3526779414947884 | |
| dc.creator | Tecedor, Natália | |
| dc.date.accessioned | 2014-09-09 | |
| dc.date.accessioned | 2016-06-02T20:00:58Z | |
| dc.date.available | 2014-09-09 | |
| dc.date.available | 2016-06-02T20:00:58Z | |
| dc.date.created | 2014-09-09 | |
| dc.date.created | 2016-06-02T20:00:58Z | |
| dc.date.issued | 2014-06-10 | |
| dc.identifier | TECEDOR, Natália. Monitoramento e modelagem hidrológica de plano de infiltração construído em escala real. 2014. 94 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2014. | |
| dc.identifier | https://repositorio.ufscar.br/handle/ufscar/4387 | |
| dc.description.abstract | The intense urbanization generated from twentieth century and the emergence of large urban centers brought about a considerable change in the use and occupation of land ; this became very waterproof resulting in increased runoff . Problems resulting from the growth of this flow we mention floods , climate change , interference in the hydrological cycle and water balance . This problem , with the passage of time has been improving sustainable urban drainage analyzing the control flow that has to be done at source infiltration , percolation and storage . The importance of this work is to know the compensatory techniques so that they can be applied in the UFSCAR campus - São Carlos - SP . This study aimed to design, build , monitor and model a plan of infiltration, built in real scale, for stormwater management of the building with an area of 3001.3 m². The funds came from Project MCT / FINEP / Action Cross Environmental and Housing 07 /2009 Drainage - MAPLU2 - . Stormwater Management Urban 2 The soil characterization was performed considering their fitness levels , grain size, permeability, degree of compaction and profile this soil. The lifting of water infiltration into the soil testing was conducted with double ring . There was an technical compensatory plan infiltration met the six physical aspects , three urban and infrastructure aspects , environmental aspects and two health and two socioeconomic aspects . The method adopted for the design was the envelope -curve , using a return period of 10 years. Through electronic equipment and measurements of precipitation 32 actual rainfall events were monitored . In this period there were no leakage of the infiltration plan representing these events , an efficiency of 100 % in reducing runoff volume. The modeling technique was using the method of PULS . This model however was considered difficult to apply this technique , that due to uncertainties regarding the areas of infiltration by high initial infiltration capacity of the soil and the fact that the water has preferred areas in infiltration plan. | |
| dc.publisher | Universidade Federal de São Carlos | |
| dc.publisher | BR | |
| dc.publisher | UFSCar | |
| dc.publisher | Programa de Pós-Graduação em Engenharia Urbana - PPGEU | |
| dc.rights | Acesso Aberto | |
| dc.subject | Drenagem urbana | |
| dc.subject | Técnicas compensatórias | |
| dc.subject | Plano de infiltração | |
| dc.subject | Urban Drainage | |
| dc.subject | Compensatory techniques | |
| dc.subject | Infiltration Plan | |
| dc.title | Monitoramento e modelagem hidrológica de plano de infiltração construído em escala real | |
| dc.type | Tesis | |