The dynamic behaviour of a buried water pipe and its effect on leak location using acoustic methods
Fecha
2013-09-16Registro en:
Key Engineering Materials, v. 569-570, p. 1194-1201.
1013-9826
10.4028/www.scientific.net/KEM.569-570.1194
2-s2.0-84883675068
Autor
University of Southampton
Universidade Estadual Paulista (Unesp)
South Staffs Water plc
Hydrosave Ltd.
Institución
Resumen
Leakage in buried pipes is one of the main concerns for water companies due to the scarcity of potable water sources. Older metallic pipelines have been replaced by plastic pipes in such systems, which makes it more difficult to locate leaks using acoustics and vibration. This is mainly because of the high attenuation of leak signals caused by the damping in the pipe wall. To investigate acoustic methods in leak location in controlled conditions, a bespoke test rig was constructed in the UK. In this paper, data from this test-rig is used to discuss some issues that arise when using two contemporary correlators. Of particular interest, is the way in which a resonance in the system can have a profound effect on the estimate of the position of the leak depending on the way in which the leak noise signals are processed. © (2013) Trans Tech Publications.