dc.contributorCiudad Universitaria
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:30:30Z
dc.date.available2014-05-27T11:30:30Z
dc.date.created2014-05-27T11:30:30Z
dc.date.issued2013-08-29
dc.identifierRevista MVZ Cordoba, v. 18, n. 2, p. 3492-3500, 2013.
dc.identifier0122-0268
dc.identifier1909-0544
dc.identifierhttp://hdl.handle.net/11449/76360
dc.identifierS0122-02682013000200010
dc.identifierWOS:000323351700010
dc.identifier2-s2.0-84882942822
dc.identifier2-s2.0-84882942822.pdf
dc.identifier9772438921794907
dc.description.abstractTo compare the removal efficiency of solids, turbidity and apparent color between a conventional and a column settling tanks in a recirculating aquaculture system (RAS) for tilapia farming. Materials and methods. Tilapia with a stocking density between 30 and 33 kg/m3 were cultured in a RAS consisting of a water level control box, PVC piping system, three plastic tanks for culture, conventional horizontal flow settling tank (Con.ST), column vertical flow settling tank (Col.ST), three phase fluidized bed reactor, oxygen transfer reactor, air compressor, air blower, centrifugal pump. The Con.ST operated at a volume of 1.4 m3 and hydraulic retention time (HRT) of 2.94 h; and was drained weekly for washing and sludge collection, representing a 55%discharge of system water volume. The Col.ST operated with a volume of 0.30 m3 and HRT of 0.553 h. Three daily partial draining operations were executed, representing a discharge of 50% of the system volume. Results. The mean solids removal efficiencies were: 34.01 and 44.44%for total solids; 64.45 and 71.71% for suspended solids; 21.10 and 45.65% volatile solids; 65.51% and 62.79% for turbidity; and 56.37 and 50.91% for apparent color, respectively for Con.ST and Col.ST. Conclusions. The two settling devices are useful on removal of the studied parameters and presented similar performance on turbidity and apparent color removal; however, the Col.ST was more efficient than Con.ST for solids removal, requires less space, less volume and requires less discharge water volume, displaying feasibility for its use on RAS.
dc.languagepor
dc.relationRevista MVZ Cordoba
dc.relation0.162
dc.relation0,173
dc.relation0,173
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectAquaculture
dc.subjectGravimetry
dc.subjectRAS (Source: DeCS).
dc.subjectRecirculation
dc.subjectTilapia
dc.titleDesempeño de tanques decantadores de sólidos en un sistema de recirculación para producción de tilapia
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución