Artículos de revistas
Validation of microbiological assay for determination of cefuroxime in injectable preparations
Fecha
2012-08-22Registro en:
Latin American Journal of Pharmacy, v. 31, n. 5, p. 746-750, 2012.
0326-2383
2-s2.0-84865083152
Autor
Universidade Estadual Paulista (Unesp)
Institución
Resumen
The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.