Artículos de revistas
Integrated analysis of halogenated organic pollutants in sub-millilitre volumes of venous and umbilical cord blood sera
Date
2010-03-01Registration in:
Analytical and Bioanalytical Chemistry, v. 396, n. 6, p. 2265-2272, 2010.
1618-2642
1618-2650
10.1007/s00216-010-3460-y
2-s2.0-77951295081
2543372149131902
Author
Institute of Environmental Assessment and Water Research (IDÆA-CSIC)
Université de Lille 2
Universidade Estadual Paulista (Unesp)
Institutions
Abstract
A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.
Subjects
Related items
Showing items related by title, author, creator and subject.
-
Relationship between irisin concentration and serum cytokines in mother and newborn
Estibalitz Laresgoiti Servitje; Gerardo de Jesús García Rivas -
Increased levels of serum γ-glutamyltransferase and uric acid on metabolic, hepatic and kidney parameters in subjects at high altitudes
Unknown author (De Gruyter, 2014)Background: Currently there are no studies on γ-glutamyltransferase (γGT) levels at high altitude or on the relationship between γGT, uric acid and several dysfunctions. The aim of the study was to determine the association ... -
Integrated analysis of halogenated organic pollutants in sub-millilitre volumes of venous and umbilical cord blood sera
Grimalt, Joan O.; Howsam, Mike; Carrizo, Daniel; Otero, Raquel; Marchi, Mary Rosa Rodrigues de; Vizcaino, Esther