dc.contributor | Universidade de São Paulo (USP) | |
dc.contributor | Universidade do Sagrado Coração (USC) | |
dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:24:35Z | |
dc.date.available | 2014-05-27T11:24:35Z | |
dc.date.created | 2014-05-27T11:24:35Z | |
dc.date.issued | 2010-01-01 | |
dc.identifier | Laser Physics, v. 20, n. 1, p. 285-290, 2010. | |
dc.identifier | 1054-660X | |
dc.identifier | 1555-6611 | |
dc.identifier | http://hdl.handle.net/11449/71508 | |
dc.identifier | 10.1134/S1054660X10010172 | |
dc.identifier | 2-s2.0-76849098494 | |
dc.identifier | 6914969526213393 | |
dc.description.abstract | The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd. | |
dc.language | eng | |
dc.relation | Laser Physics | |
dc.relation | 1.158 | |
dc.relation | 0,345 | |
dc.rights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Composite resins | |
dc.subject | Degree of conversion | |
dc.subject | Halogen curing | |
dc.subject | Kruskal | |
dc.subject | Light-curing units | |
dc.subject | Metallic mold | |
dc.subject | Monomer conversions | |
dc.subject | Resin composites | |
dc.subject | Room temperature | |
dc.subject | Statistical analysis | |
dc.subject | Statistically significant difference | |
dc.subject | Dental composites | |
dc.subject | Heating | |
dc.subject | Light emitting diodes | |
dc.subject | Regression analysis | |
dc.subject | Resins | |
dc.subject | Curing | |
dc.title | Effect of pre-heating resin composite and light-curing units on monomer conversion | |
dc.type | Artículos de revistas | |