dc.description.abstractThe aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.
dc.languageeng
dc.relationBrazilian Oral Research
dc.relation1.223
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectDental cavity preparation
dc.subjectDiamond
dc.subjectTechnology, dental
dc.subjectUltrasonography
dc.subjectdiamond
dc.subjectanimal
dc.subjectcattle
dc.subjectclinical trial
dc.subjectcontrolled clinical trial
dc.subjectcontrolled study
dc.subjectdental surgery
dc.subjectechography
dc.subjectequipment design
dc.subjectinstrumentation
dc.subjectmethodology
dc.subjectnonparametric test
dc.subjectrandomized controlled trial
dc.subjectsurface property
dc.subjecttooth pulp
dc.subjectultrasound therapy
dc.subjectAnimals
dc.subjectCattle
dc.subjectDental Cavity Preparation
dc.subjectDental Pulp Cavity
dc.subjectEquipment Design
dc.subjectStatistics, Nonparametric
dc.subjectSurface Properties
dc.subjectUltrasonic Therapy
dc.titleInfluence of the power level of an ultra-sonic system on dental cavity preparation