Artículos de revistas
Evaluation of transfer impressions for osseointegrated implants at various angulations
Fecha
2004-12-01Registro en:
Implant Dentistry, v. 13, n. 4, p. 358-366, 2004.
1056-6163
10.1097/01.id.0000144509.58901.f7
2-s2.0-11444261183
4438747643373395
5335208171935802
Autor
Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
Institución
Resumen
The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.
Materias
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Accuracy of impression techniques for implants. Part 1 - Influence of transfer copings surface abrasion
Assunção, Wirley Goncalves; Cardoso, Alessandra; Gomes, Erica Alves; Tabata, Lucas Fernando; Santos, Paulo Henrique dos -
Accuracy of impression techniques for implants. Part 1 - Influence of transfer copings surface abrasion
Universidade Estadual Paulista (Unesp); Dental Practice (2008-12-01)Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = ... -
Accuracy of impression techniques for implants. Part 1 - Influence of transfer copings surface abrasion