Artículos de revistas
The effect of adhesive and flowable composite on postoperative sensitivity: 2-Week results
Fecha
2004-11-01Registro en:
Quintessence International, v. 35, n. 10, p. 777-784, 2004.
0033-6572
WOS:000225359900002
2-s2.0-4944221152
Autor
Universidade de Mogi das Cruzes (UMC)
Universidade Bandeirante de São Paulo (UNIBAN)
Universidade Cruzeiro do Sul
Universidade Estadual Paulista (Unesp)
University of Minnesota
Institución
Resumen
Objective: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. Method and materials: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect. Results: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed. Conclusion: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.
Materias
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Fatigue resistance of the bond of a glass-infiltrated alumina ceramic to human dentin
Baldissara, Paolo; Valandro, Luiz Felipe; Monaco, Carlo; Ferrari, Marco; Bottino, Marco Antonio; Scotti, Roberto -
Fatigue resistance of the bond of a glass-infiltrated alumina ceramic to human dentin
University of Bologna; Federal University of Santa Maria; University of Siena; Universidade Estadual Paulista (Unesp); Dept. of Restorative Dentistry (2006-05-09)Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance ... -
Fatigue resistance of the bond of a glass-infiltrated alumina ceramic to human dentin
University of Bologna; Federal University of Santa Maria; University of Siena; Universidade Estadual Paulista (Unesp); Dept. of Restorative Dentistry (2006-05-09)Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance ...