Performance characteristics of bioassay, UV-spectrophotometry and high performance liquid chromatographic determination of sparfloxacin in tablets
Date
2001-01-01Registration in:
Revista Brasileira de Ciencias Farmaceuticas/Brazilian Journal of Pharmaceutical Sciences, v. 37, n. 2, p. 171-175, 2001.
1516-9332
2-s2.0-0035150570
Author
Universidade Estadual Paulista (Unesp)
Institutions
Abstract
The microbiological bioassay, the UV-spectrophotometry and the high performance liquid chromatography (HPLC) methods for assaying sparfloxacin in tablets were compared. The accuracy, repeatability, and precision of each method was assessed and precise. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate and precise. The microbiological bioassay and HPLC are more specific than UV-spectrophotometric analysis. However, the microbiological bioassay requires 20 h to get results, and HPLC is the most expensive analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.