Artículos de revistas
Pre-concentration of Cd(II), Cr(III), Cu(II) and Ni(II) on a column packed with free carboxymethylcellulose (CMCH)
Fecha
1997-12-01Registro en:
Journal of the Brazilian Chemical Society, v. 8, n. 4, p. 333-337, 1997.
0103-5053
10.1590/S0103-50531997000400003
S0103-50531997000400003
WOS:A1997XV68500003
2-s2.0-3042863419
2-s2.0-3042863419.pdf
6981448637456391
0000-0003-4179-0574
Autor
Universidade Estadual Paulista (Unesp)
Institución
Resumen
Carboxymethylcellulose packed in to a glass column was used to pre-concentrate metallic cations from aqueous solutions. The pre-concentrated metal cations are directly eluted from the column using 5.0 mL of 1.0 mol L -1 hydrochloric acid. The optimum pre-concentration conditions are given (glass column, 16 cm length, 0.80 cm i.d., stationary phase height of 12 cm, flow-rate, 1.5 mL min -1). The recuperation efficiency achieved is greater than 95%, while the enrichment factor is 10 for 50 mL of solution (0.50 mg L -1 each).