dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:14:41Z
dc.date.available2014-05-20T15:14:41Z
dc.date.created2014-05-20T15:14:41Z
dc.date.issued2004-12-01
dc.identifierCiência Rural. Universidade Federal de Santa Maria (UFSM), v. 34, n. 6, p. 1841-1847, 2004.
dc.identifier0103-8478
dc.identifierhttp://hdl.handle.net/11449/29304
dc.identifier10.1590/S0103-84782004000600027
dc.identifierS0103-84782004000600027
dc.identifierS0103-84782004000600027.pdf
dc.identifier1497433265390194
dc.identifier4065105014625753
dc.identifier0000-0002-9211-4093
dc.description.abstractO trabalho teve por objetivo comparar a consolidação óssea e a função do membro, em 18 gatos com fraturas transversas femorais tratadas com pino intramedular e fixador esquelético externo tipo Ia (grupo I, n=9) ou com pino intramedular associado ao fixador externo em uma configuração tie-in (grupo II, n=9). Independente da configuração utilizada, após a remoção dos implantes, todos os animais apresentaram função normal do membro operado. Não houve diferença entre os grupos em relação à densidade mineral óssea do calo externo mensurada pela densitometria óptica por imagens radiográficas. O tempo para consolidação foi significativamente maior para as fraturas tratadas com pino intramedular e fixador tipo Ia. As fraturas que receberam a configuração tie-in tiveram menos proliferação de calo ósseo.
dc.description.abstractThe aim of this study was to compare bone healing and limb function in 18 cats with transverse femoral fractures treated with either intramedullary pin and a type Ia external skeletal fixator (Group 1, n=9) or a tie-in configuration (Group 1, n=9). All animals showed normal function of the operated limb after implant removal, independently of the configuration used. The optic bone densitometry in radiographic images showed no difference in bone mineral density of the external bone callus between the groups. Fractures treated with intramedullary pin and type Ia external fixator had significantly more time to fracture healing, and fractures treated with the tie-in configuration had less proliferation of bone callus.
dc.languagepor
dc.publisherUniversidade Federal de Santa Maria (UFSM)
dc.relationCiência Rural
dc.relation0.525
dc.relation0,337
dc.rightsAcesso aberto
dc.sourceSciELO
dc.subjectgatos
dc.subjectfixador
dc.subjectfratura
dc.subjectfêmur
dc.subjectcats
dc.subjectfixator
dc.subjectfracture
dc.subjectfemur
dc.titleImobilização de fraturas femorais em gatos usando pino intramedular conectado ou não ao fixador esquelético externo
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución