dc.contributorUniv Bern
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:25Z
dc.date.accessioned2014-05-20T13:44:55Z
dc.date.available2013-09-30T18:31:25Z
dc.date.available2014-05-20T13:44:55Z
dc.date.created2013-09-30T18:31:25Z
dc.date.created2014-05-20T13:44:55Z
dc.date.issued2008-01-01
dc.identifierCaries Research. Basel: Karger, v. 42, n. 4, p. 297-304, 2008.
dc.identifier0008-4166
dc.identifierhttp://hdl.handle.net/11449/15762
dc.identifier10.1159/000148162
dc.identifierWOS:000258317800010
dc.description.abstractThis study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces. Copyright (C) 2008 S. Karger AG, Basel.
dc.languageeng
dc.publisherKarger
dc.relationCaries Research
dc.relation1.243
dc.relation0,579
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectcaries detection
dc.subjectDIAGNOdent
dc.subjectDIAGNOdent pen
dc.subjectfluorescence camera
dc.subjectInternational Caries Detection and Assessment System
dc.subjectlaser fluorescence
dc.subjectocclusal caries
dc.titlePerformance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución