Artículos de revistas
LC Evaluation of In Vitro Release of AZT from Microemulsions
Fecha
2009-06-01Registro en:
Chromatographia. Wiesbaden: Vieweg, v. 69, p. 207-211, 2009.
0009-5893
10.1365/s10337-009-1015-1
WOS:000267330400016
9129780536724256
Autor
Universidade Estadual Paulista (Unesp)
Institución
Resumen
A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 mu g mL(-1). The RSD values (0.7-4.3%) and percentage recovery (88.1-109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 mu g mL(-1). Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.