dc.creatorCaorsi P., Beatriz
dc.creatorPezzani Valenzuela, Marcela
dc.creatorSakurada Zamora, Andrea
dc.creatorUlloa Flores, María Teresa
dc.creatorLatorre Ordóñez, Paz Verónica
dc.date.accessioned2011-10-20T15:15:07Z
dc.date.available2011-10-20T15:15:07Z
dc.date.created2011-10-20T15:15:07Z
dc.date.issued2011-02
dc.identifierREVISTA CHILENA DE INFECTOLOGIA Volume: 28 Issue: 1 Pages: 14-18 Published: FEB 2011
dc.identifier0716-1018
dc.identifierhttps://repositorio.uchile.cl/handle/2250/124235
dc.description.abstractBackground: An extremely clean area is required for preparation of sterile pharmaceutical compounds, in compliance with international standards, to minimize the probability of microbial contamination. Aim: To evaluate the bacteriological quality of the air in the Sterile Pharmaceutical Preparation Unit of the University of Chile's Clinical Hospital and to set up alerts and action levels of bacterial growth. Methods: We studied eight representative sites of our Unit on a daily basis from January to February 2005 and twice a week from June 2005 to February 2006. We collected 839 samples of air by impact in the Petri dish. Results: 474 (56.5%) samples were positive; 17 (3.5%) of them had an inappropriate bacterial growth (2% of total samples). The samples from sites 1 and 2 (big and small biosafety cabinets) were negative. The countertop and transfer area occasionally exceeded the bacterial growth limits. The most frequently isolated bacteria were coagulase-negative staphylococci, Micrococcus spp and Corynebacterium spp, from skin microbiota, and Bacillus spp, an environmental bacteria. Conclusions: From a microbiological perspective, the air quality in our sterile preparation unit complied with international standards. Setting institutional alerts and action levels and appropriately identifying bacteria in sensitive areas permits quantification of the microbial load and application of preventive measures.
dc.languagees
dc.publisherSOC CHILENA INFECTOLOGIA
dc.subjectindoor air quality
dc.titleCalidad microbiológica del aire de una unidad de preparados farmacéuticos estériles
dc.typeArtículo de revista


Este ítem pertenece a la siguiente institución