dc.creatorPellegrino Vidal, Rocio
dc.creatorIbañez, Gabriela Alejandra
dc.creatorEscandar, Graciela Monica
dc.date.accessioned2018-07-19T17:35:43Z
dc.date.accessioned2018-11-06T12:37:08Z
dc.date.available2018-07-19T17:35:43Z
dc.date.available2018-11-06T12:37:08Z
dc.date.created2018-07-19T17:35:43Z
dc.date.issued2016-10
dc.identifierPellegrino Vidal, Rocio; Ibañez, Gabriela Alejandra; Escandar, Graciela Monica; A green method for the quantification of plastics-derived endocrine disruptors in beverages by chemometrics-assisted liquid chromatography with simultaneous diode array and fluorescent detection; Elsevier Science; Talanta; 159; 10-2016; 336-343
dc.identifier0039-9140
dc.identifierhttp://hdl.handle.net/11336/52651
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1868307
dc.description.abstractThe aim of this study was to develop a novel analytical method for the determination of bisphenol A, nonylphenol, octylphenol, diethyl phthalate, dibutyl phthalate and diethylhexyl phthalate, compounds known for their endocrine-disruptor properties, based on liquid chromatography with simultaneous diode array and fluorescent detection. Following the principles of green analytical chemistry, solvent consumption and chromatographic run time were minimized. To deal with the resulting incomplete resolution in the chromatograms, a second-order calibration was proposed. Second-order data (elution time-absorbance wavelength and elution time-fluorescence emission wavelength matrices) were obtained and processed by multivariate curve resolution-alternating least-squares (MCR-ALS). Applying MCR-ALS allowed quantification of the analytes even in the presence of partially overlapped chromatographic and spectral bands among these compounds and the potential interferents. The obtained results from the analysis of beer, wine, soda, juice, water and distilled beverage samples were compared with gas chromatography-mass spectrometry (GC-MS). Limits of detection (LODs) in the range 0.04–0.38 ng mL−1 were estimated in real samples after a very simple solid-phase extraction. All the samples were found to contain at least three EDs, in concentrations as high as 334 ng mL−1.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.talanta.2016.06.049
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S003991401630474X
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectBEVERAGES
dc.subjectENDOCRINE DISRUPTORS
dc.subjectLIQUID CHROMATOGRAPHY
dc.subjectSECOND-ORDER CALIBRATION
dc.titleA green method for the quantification of plastics-derived endocrine disruptors in beverages by chemometrics-assisted liquid chromatography with simultaneous diode array and fluorescent detection
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución