Artículos de revistas
Composite connections in slim-floor system: An experimental study
Fecha
2012Registro en:
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, OXFORD, v. 68, n. 1, supl. 4, Part 1-2, pp. 78-88, JAN, 2012
0143-974X
10.1016/j.jcsr.2011.07.006
Autor
Nardin, Silvana de
El Debs, Ana Lucia Homce de Cresce
Institución
Resumen
This paper reports the results of full-scale tests in beam-to-column connections for composite slim floor systems, including tests on Bare Steel connection and composite connection. The tested system consists of a concrete-filled composite column and a composite floor where an asymmetric steel beam is connected to a composite column by shear steel plates. Tests results previously obtained on partially encased composite beams were used to define the position of the headed studs in the slim floor system. Based on the obtained results of connections, the composite and Bare Steel connection behaved as semi-rigid and nominally pinned respectively. The tests results also indicated a significant contribution of the slim floor to the moment capacity of the connection. (C) 2011 Elsevier Ltd. All rights reserved.