Artículos de revistas
Development and validation of high performance liquid chromatographic and UV-derivative spectrophotometric methods for the determination of sotalol hydrochloride in tablets
Fecha
2008Registro en:
ANALYTICAL LETTERS, v.41, n.11, p.2044-2057, 2008
0003-2719
10.1080/00032710802209342
Autor
SANTORO, Maria Ines Rocha Miritello
TSUBONE, Camila
GOMES, Fabio Pereira
KEDOR-HACKMANN, Erika Rosa Maria
GARCIA, Pedro Lopez
Institución
Resumen
High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.