dc.creator | BARRETTO-LOPES, Klaus | |
dc.creator | DOMINGUEZ, Gladys Cristina | |
dc.creator | TORTAMANO, André | |
dc.creator | ROSSI, Jesualdo Luiz | |
dc.creator | VIGORITO, Julio Wilson | |
dc.date.accessioned | 2012-03-26T20:33:08Z | |
dc.date.accessioned | 2018-07-04T14:21:52Z | |
dc.date.available | 2012-03-26T20:33:08Z | |
dc.date.available | 2018-07-04T14:21:52Z | |
dc.date.created | 2012-03-26T20:33:08Z | |
dc.date.issued | 2010 | |
dc.identifier | Dental Press Journal of Orthodontics, v.15, n.4, p.38e1-38e6, 2010 | |
dc.identifier | 2176-9451 | |
dc.identifier | http://producao.usp.br/handle/BDPI/11280 | |
dc.identifier | 10.1590/S2176-94512010000400006 | |
dc.identifier | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512010000400006 | |
dc.identifier | http://www.scielo.br/pdf/dpjo/v15n4/06.pdf | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1609079 | |
dc.description.abstract | OBJETIVO: o propósito do presente estudo é avaliar o limite de resistência à flexão de um protótipo de mini-implante desenvolvido para ancoragem do aparelho de Herbst. MÉTODOS: após a realização de um cálculo do tamanho da amostra, quatro corpos de prova contendo os protótipos de mini-implantes foram submetidos a uma força de flexão por engastamento simples, utilizando-se uma máquina universal de ensaios mecânicos, sendo calculado o limite de resistência à força de flexão. RESULTADOS: após os ensaios mecânicos, os novos mini-implantes apresentaram o limite de resistência à força de flexão de 98,2kgf, que foi o menor valor encontrado. CONCLUSÃO: os protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst foram capazes de suportar forças de flexão maiores do que as forças de mordida descritas na literatura. | |
dc.description.abstract | AIM: The purpose of this study was to evaluate the limit of flexural strength of a mini-implant prototype designed for Herbst appliance anchorage. METHODS: After sample size calculation, four specimens with the new mini-implant were submitted to a single cantilever flexure test using a universal testing machine. The limit of flexural force strength was calculated. RESULTS: The mini-implant prototype showed a limit of flexural force strength of 98.2 kgf (982 N), that was the lowest value found. CONCLUSION: The mini-implant prototype designed for Herbst appliance anchorage can withstand flexural forces higher than the maximum human bite forces reported in the literature. | |
dc.language | por | |
dc.publisher | Dental Press International | |
dc.relation | Dental Press Journal of Orthodontics | |
dc.rights | Copyright Dental Press International | |
dc.rights | openAccess | |
dc.subject | Aparelhos ortodônticos | |
dc.subject | Ortodontia | |
dc.subject | Aparelho de Herbst | |
dc.subject | Mini-implante | |
dc.subject | Orthodontic appliances | |
dc.subject | Orthodontics | |
dc.subject | Herbst appliance | |
dc.subject | Mini-implant | |
dc.title | Avaliação in vitro da resistência à flexão de um protótipo de mini-implante desenvolvido para ancoragem do aparelho de Herbst | |
dc.type | Artículos de revistas | |