dc.creatorDIAS, Larissa Lustosa Lima
dc.creatorGIOVANI, Alessandro Rogério
dc.creatorSILVA SOUSA, Yara Teresinha Corrêa
dc.creatorVANSAN, Luiz Pascoal
dc.creatorALFREDO, Edson
dc.creatorSOUSA-NETO, Manoel Damião
dc.creatorPAULINO, Silvana Maria
dc.date.accessioned2012-03-26T20:23:08Z
dc.date.accessioned2018-07-04T14:21:23Z
dc.date.available2012-03-26T20:23:08Z
dc.date.available2018-07-04T14:21:23Z
dc.date.created2012-03-26T20:23:08Z
dc.date.issued2009
dc.identifierJournal of Applied Oral Science, v.17, n.6, p.579-583, 2009
dc.identifier1678-7757
dc.identifierhttp://producao.usp.br/handle/BDPI/11170
dc.identifier10.1590/S1678-77572009000600008
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572009000600008
dc.identifierhttp://www.scielo.br/pdf/jaos/v17n6/v17n6a08.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1608970
dc.description.abstractOBJECTIVE: This study evaluated in vitro the influence of an eugenol-based sealer (EndoFill) on the retention of stainless steel prefabricated posts cemented with zinc phosphate and resin-based (Panavia F) cements after different periods of root canal obturation, using the pull-out test. MATERIAL AND METHODS: Sixty upper canines were decoronated and the roots were embedded in resin blocks. The specimens were distributed into 3 groups, according to the period elapsed between canal obturation and post cementation: Group I - immediately; Group II - 72 h and Group III - 4 months. The groups were subdivided according to the type of cement used for post cementation: A - zinc phosphate and B - Panavia F. Following the experimental periods, specimens were subjected to pullout test in an Instron machine with application of tensile force at a crosshead speed of 0.5 mm/min until post dislodgement. The maximum forces required for post removal were recorded (kN) and means were subjected to statistical analysis by 2-way ANOVA and Tukey-Kramer test (&#945;=0.001) RESULTS: There were statistically significant differences (p<0.01) between the posts cemented with zinc phosphate cement (0.2112 kN) and Panavia F (0.0501 kN). However, no statistically significant differences (p>0.05) were found between the three post cementation periods, regardless of the cement. CONCLUSIONS: It was concluded that the eugenol-based sealer influenced the tensile strength of the posts cemented with the resin cement, but had no influence on the time waited between root canal obturation and post space preparation/post cementation.
dc.languageeng
dc.publisherFaculdade De Odontologia De Bauru - USP
dc.relationJournal of Applied Oral Science
dc.rightsCopyright Faculdade De Odontologia De Bauru - USP
dc.rightsopenAccess
dc.subjectEndodontics
dc.subjectDentistry
dc.subjectPost
dc.subjectZinc oxide-eugenol cement
dc.titleEffect of eugenol-based endodontic sealer on the adhesion of intraradicular posts cemented after different periods
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución