Artículos de revistas
Effect of light curing unit on resin-modified glass-ionomer cements: a microhardness assessment
Fecha
2009Registro en:
Journal of Applied Oral Science, v.17, n.3, p.150-154, 2009
1678-7757
10.1590/S1678-77572009000300004
Autor
CEFALY, Daniela Francisca Gigo
MELLO, Liliam Lucia Carrara Paes de
WANG, Linda
LAURIS, José Roberto Pereira
D'ALPINO, Paulo Henrique Perlatti
Institución
Resumen
OBJECTIVE: To evaluate the microhardness of resin-modified glass-ionomer cements (RMGICs) photoactivated with a blue light-emitting diode (LED) curing light. MATERIAL AND METHODS: Thirty specimens were distributed in 3 groups: Fuji II LC Improved/GC (RM1), Vitremer/3M ESPE (RM2) and Filtek Z250/ 3M ESPE (RM3). Two commercial light-curing units were used to polymerize the materials: LED/Ultrablue IS and a halogen light/XL3000 (QTH). After 24 h, Knoop microhardness test was performed. Data were submitted to three-way ANOVA and Tukey's test at a pre-set alpha of 0.05. RESULTS: At the top surface, no statistically significant difference (p>0.05) in the microhardness was seen when the LED and QTH lights were used for all materials. At the bottom surface, microhardness mean value of RM2 was significantly higher when the QTH light was used (p<0.05). For RM1, statistically significant higher values (p<0.05) were seen when the LED light was used. No statistically significant difference (p>0.05) was seen at the bottom surface for RM3, irrespective of the light used. Top-to-bottom surface comparison showed no statistically significant difference (p>0.05) for both RMGICs, regardless of the light used. For RM3, microhardness mean value at the top was significantly higher (p<0.05) than bottom microhardness when both curing units were used. CONCLUSION: The microhardness values seen when a LED light was used varied depending on the restorative material tested.