dc.creatorHIDA, Wilson Takashi
dc.creatorYAMANE, Íris de Souza
dc.creatorMOTTA, Antonio Francisco Pimenta
dc.creatorSILVA, Marcel Tadeu
dc.creatorALVES, Emerson
dc.creatorJOSÉ JUNIOR, Newton Kara
dc.creatorNAKANO, Celso Takashi
dc.date.accessioned2012-03-26T18:55:32Z
dc.date.accessioned2018-07-04T14:17:37Z
dc.date.available2012-03-26T18:55:32Z
dc.date.available2018-07-04T14:17:37Z
dc.date.created2012-03-26T18:55:32Z
dc.date.issued2008
dc.identifierRevista Brasileira de Oftalmologia, v.67, n.3, p.119-124, 2008
dc.identifier0034-7280
dc.identifierhttp://producao.usp.br/handle/BDPI/10311
dc.identifier10.1590/S0034-72802008000300004
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802008000300004
dc.identifierhttp://www.scielo.br/pdf/rbof/v67n3/a04v67n3.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1608121
dc.description.abstractOBJETIVO: Comparar a análise da frente de onda e a sensibilidade de contraste pós-operatórias em pacientes submetidos à facoemulsificação com implante de lentes intra-oculares esféricas num olho e asféricas no olho contralateral. MÉTODOS: Este estudo prospectivo comparativo, randomizado, duplo-cego, incluiu 32 olhos de 16 pacientes. Uma avaliação oftalmológica completa foi realizada durante as visitas antes e depois da cirurgia (no primeiro, terceiro, sétimo, e nonagésimo dias pós-cirúrgicos), que incluiu acuidade visual, teste de sensibilidade ao contraste, aberrometria. Todos exames (menos aberrometr=ia) foram feitos monocularmente com pupilas não dilatadas. Os pacientes foram submetidos a facectomia ultra-sônica convencional com implante de uma lente asférica SN60WF num olho e esférica SN60ATno outro. RESULTADOS: A acuidade visual média com a melhor correção foi -0,146 LogMAR no grupo da lente intra-ocular esférica, e -0.165 logMAR no grupo da lente intra-ocular asférica sob condições fotópicas, -0,003 LogMAR sob condições mesópicas. A sensibilidade ao contraste foi semelhante em ambos os grupos tanto em condições fotópicas e mesópicas. Em relação às aberrações ópticas ocorreu uma diferença significativa nas aberrações totais (1,09 ± 0,56 no grupo asférico e 1,52 ± 1,19 no grupo esférico) e no componente esférico das aberrações de alta ordem(0,422 ± 0,202 no grupo asférico e 0,124 ± 0,087 no grupo esférico). CONCLUSÃO: As duas lentes intra-oculares promoveram uma excelente visão em situações de alto contraste, e os olhos implantados com a lente asférica tiveram menos aberrações totais e esféricas que aqueles implantados com a lente esférica.
dc.description.abstractPURPOSE: Compare the wavefront and contrast sensitivity of bilateral pseudophakic patients with aspheric in one eye and spheric intraocular lenses in the other. METHODS: This prospective, comparative, randomized study, double masked, included 32 eyes of 16 patients. A complete ophthalmic evaluation was done before, and after surgery at days 1,3, 7 and 90, and included best corrected visual acuity, the contrast sensitivity, under photopic and mesopic conditions, and aberrometry. Almost all exams were done monocularly with undilated pupils (aberrometry under pharmacological dilatation). The patients eyes were operated with conventional phacoemulsification, with aspheric intraocular lenses in one eye, and spherical in the other. RESULTS: The visual acuity with the best correction was -0.146 in the spheric group, and -0.165 logMAR in the aspheric group in photopic conditions, and 0.024 and -0.003 LogMAR under mesopic conditions. The contrast sensitivity under photopic and mesopic conditions was similar comparing the two groups. In regard to optical aberrations there was a significant diference between the total (1.09 ± 0.56 in the aspheric, and 1.52± 1.19 in the spherical group) and spherical component of high order aberrations (0.422± 0.202 in spheric group and 0.124 ± 0.087 in the aspheric group). CONCLUSION: Both groups reached excellent postoperative visual acuity in high contrast situations, however aspheric intraocular lenses group had lower total and spherical aberrations, comparing to the spheric intraocular lenses group.
dc.languagepor
dc.publisherSociedade Brasileira de Oftalmologia
dc.relationRevista Brasileira de Oftalmologia
dc.rightsCopyright Sociedade Brasileira de Oftalmologia
dc.rightsopenAccess
dc.subjectLentes intra-oculares
dc.subjectFacoemulsificação
dc.subjectSensibilidades de contraste
dc.subjectVisão
dc.subjectLenses, intraocular
dc.subjectPhacoemulsification
dc.subjectContrast sensitivity
dc.subjectVision
dc.titleComparação da análise da frente de onda e da sensibilidade ao contraste em olhos pseudofácicos com implante de lentes intra-oculares esférica e asférica
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución