Expression of apoptosis in human saphenous vein grafts in restoration of blood flow through coronary bypass surgery
Fecha
2009Registro en:
Revista Brasileira de Cirurgia Cardiovascular, v.24, n.3, p.312-317, 2009
0102-7638
10.1590/S0102-76382009000400009
Autor
TIRAPELLI, Luís Fernando
TIRAPELLI, Daniela Pretti da Cunha
DALIO, Marcelo Bellini
RODRIGUES, Alfredo José
ÉVORA, Paulo Roberto Barbosa
Institución
Resumen
OBJECTIVE: To investigate the possible role of apoptosis on brief distensions of human saphenous veins at different pressures. METHODS: Fresh isolated grafts of human saphenous vein were assigned as control or distended (D) for fifteen seconds at 100, 200 and 300 mmHg. The degree of apoptotic caspases 3, 8, 9 and anti-apoptotic protein Bcl-2 expression were assessed by immunohistochemistry. RESULTS: Fresh isolated segments of distended human saphenous veins presented similar apoptotic protein expression when compared with control veins. However, the Bcl-2 expression was significantly higher in the 300 mmHg distended segments compared with the control vein. CONCLUSION: These findings show that intact segments of human saphenous veins submitted to distensions at different pressures have similar apoptotic proteins expression when compared with non-distended control veins. Therefore, brief distensions commonly performed during surgical harvesting do not trigger apoptosis, and probably are not involved on the physiopathological mechanisms that lead to graft failure OBJETIVO: Investigar o possível papel da apoptose em distensões breves de veias safenas humanas em diferentes pressões. MÉTODOS: Segmentos frescos isolados de veia safena humana foram distribuídos em 4 grupos: controle ou distendidos (D) por quinze segundos a 100, 200 e 300 mmHg. O grau de apoptose das caspases 3, 8, 9 e expressão da proteína anti-apoptótica Bcl-2 foram avaliados por imuno-histoquímica. RESULTADOS: Segmentos frescos distendidos isolados de veias safenas humanas apresentaram expressão protéica para apoptose similar às veias controle. No entanto, a expressão de Bcl-2 foi significativamente maior nos segmentos distendidos a 300 mmHg, quando comparados à veia controle. CONCLUSÃO: Estes achados demonstram que segmentos intactos de veias safenas humanas submetidos a distensões em diferentes pressões têm expressão de proteínas apoptóticas similares quando comparados com veias controle nãodistendidas. Por conseguinte, breves distensões comumente realizadas durante a coleta cirúrgica não ativam o processo de apoptose e, provavelmente, não estão envolvidas em mecanismos fisiopatológicos que levam à falência do enxerto