dc.creatorOLIVEIRA, Walter Luiz Andrade de
dc.creatorDE NARDIN, Silvana
dc.creatorEL DEBS, Ana Lucia H. de C.
dc.date.accessioned2012-03-26T01:45:01Z
dc.date.accessioned2018-07-04T13:53:21Z
dc.date.available2012-03-26T01:45:01Z
dc.date.available2018-07-04T13:53:21Z
dc.date.created2012-03-26T01:45:01Z
dc.date.issued2009
dc.identifierRem: Revista Escola de Minas, v.62, n.1, p.73-85, 2009
dc.identifier0370-4467
dc.identifierhttp://producao.usp.br/handle/BDPI/4248
dc.identifier10.1590/S0370-44672009000100011
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0370-44672009000100011
dc.identifierhttp://www.scielo.br/pdf/rem/v62n1/a11v62n1.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1603049
dc.description.abstractSão apresentados os resultados experimentais de 32 pilares mistos preenchidos de seção circular, submetidos à compressão axial, para os quais foi avaliada a influência dos seguintes parâmetros: resistência à compressão do concreto, relação comprimento/diâmetro (L/D) e espessura do tubo de aço (t). Os valores experimentais de força máxima foram comparados com aqueles resultantes da aplicação da formulação apresentada na NBR 8800:2008 e no EN 1994-1-1:2004 (Eurocode 4 - EC4), extrapolando-se os resultados para valores de resistência do concreto não previstos por essas normas. Os perfis de aço com relação comprimento/diâmetro (L/D) de 3, 5, 7 e 10 foram preenchidos com concretos de resistências à compressão de 30, 60, 80 e 100MPa. Os resultados da comparação entre valores de força última experimental e teórica mostraram que as normas avaliadas apresentam bons resultados. A NBR 8800 apresenta resultados conservadores ao passo que o EC4 apresenta, em média, valores de força resistente não conservadores. A correlação tende a piorar para concretos de resistência menor.
dc.description.abstractIn this paper results of tests on 32 concrete-filled steel tubular columns under axial load are reported. The test parameters were the concrete compressive strength, the column slenderness (L/D) and the wall thickness (t). The test results were compared with predictions from the codes NBR 8800:2008 and EN 1994-1-1:2004 (EC4). The columns were 3, 5, 7 and 10 length to diameter ratios (L/D) and were tested with 30MPa, 60MPa, 80MPa and 100MPa concrete compressive strengths. The results of ultimate strength predicted by codes showed good agreement with experimental results. The results of NBR 8800 code were the most conservative and the EC4 showed the best results, in mean, but it was not conservative for usual concrete-filled short columns.
dc.languagepor
dc.publisherEscola de Minas
dc.relationRem: Revista Escola de Minas
dc.rightsCopyright Escola de Minas
dc.rightsopenAccess
dc.subjectPilares mistos preenchidos
dc.subjectSeção circular
dc.subjectResultados experimentais
dc.subjectCompressão axial
dc.subjectForça normal resistente
dc.subjectConcrete-filled columns
dc.subjectCircular section
dc.subjectTest results
dc.subjectAxial load
dc.subjectAxial strength
dc.titleDimensionamento de pilares preenchidos de seção circular submetidos à compressão simples, segundo a NBR 8800:2008 e Eurocode 4:2004: comparação com resultados experimentais