Brasil | Tesis

Brazilian version of the Short Physical Performance Battery - SPPB: cross-cultural adaptation and reliability study

dc.creatorNakano, Marcia Mariko
dc.date2007
dc.date2007-02-22T00:00:00Z
dc.date2017-03-29T11:26:39Z
dc.date2017-07-18T13:02:13Z
dc.date2017-03-29T11:26:39Z
dc.date2017-07-18T13:02:13Z
dc.date.accessioned2018-03-29T04:25:39Z
dc.date.available2018-03-29T04:25:39Z
dc.identifier(Broch.)
dc.identifierNAKANO, Marcia Mariko. Versão brasileira da Short Physical Performance Battery SPPB: adaptação cultural e estudo da confiabilidade. 2007. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação, Campinas, SP. Disponível em: <http://libdigi.unicamp.br/document/?code=vtls000412296>. Acesso em: 29 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/252485
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1345624
dc.descriptionOrientador: Maria Jose D'Elboux Diogo
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação
dc.descriptionResumo: O presente estudo teve como objetivos realizar a adaptação cultural e avaliar a confiabilidade do instrumento Short Physical Performance Battery (SPPB) para a população idosa brasileira. Foram adotadas as etapas metodológicas recomendadas pela literatura especializada, como: tradução, retro-tradução, avaliação por um comitê de juízes, pré-teste e análise da confiabilidade do instrumento na versão brasileira. No pré-teste participaram 27 profissionais da área da saúde e 38 idosos, sendo 30 mulheres (78,95%), com média de idade de 71,26 anos (±9,03). Se algum item do instrumento apresentasse mais de 15% de não entendimento, relatado pelos avaliadores ou pelos idosos, a questão era reformulada e reaplicada. Para analisar a confiabilidade da versão final da SPPB, duas fisioterapeutas administraram o teste numa amostra de 30 idosos com média de idade de 77 anos (±9,51), sendo 17 do gênero feminino (57,67%). As análises de confiabilidade apresentaram as seguintes medidas: consistência interna (a=0,725), por meio do coeficiente alfa de Cronbach; interobservador (ICC=0,996) e teste-reteste (ICC=0,876), as duas últimas, por meio do coeficiente de correlação intra-classe (ICC), com p<0,001. Analisou-se também a correlação de escore de cada teste versus o escore total da SPPB, por meio do coeficiente de correlação de Spearman, resultando em: r=0,703 para o teste de equilíbrio, r=0,898 para teste de velocidade de marcha e r=0,769 para o teste de levantar da cadeira, todos com p<0,0001. Concluiu-se que a versão brasileira da SPPB apresentou boa confiabilidade nos idosos estudados, ensejando recomendar outras análises psicométricas, a fim de se confirmar a validade deste instrumento na população idosa brasileira
dc.descriptionAbstract: This study was intended to carry out a cross-cultural adaptation and to evaluate the reliability of the Short Physical Performance Battery ? SPPB for the Brazilian elderly population. The methodological stages recommended by specialized literature were adopted: translation, back-translation, expert committee, pre-test and evaluation of the reliability of the Brazilian version. The pre-test consisted of a sample of 38 elderly (78.95% were women), at an age average of 71.26 years (SD=9, 03) and the involvement of 27 health care professionals. If more than 15% of therapists or patients reported difficulty in understanding any item, such item was reformulated and reapplied. To verify the reliability of the SPPB final version, two physiotherapists checked out other 30 elderly, at an age average of 77.03 (SD=9.51) years, 17 of them were women (57.67%). The reliability analysis showed the following measurements: internal consistency (a=0.725), according to Cronbach?s coefficient; interobservers (ICC=0.996) and test-retest (ICC=0.876), the last two ones, from intraclass correlation coefficient (p<0.001). Each test score as compared to SPPB total score was also analysed, according to Spearman?s correlation coefficient, resulting: r=0.703 to the balance test, r=0.898 to the gait speed test and r=0.769 to the chair stands test (all p<0.0001). In conclusion, the SPPB Brazilian version applied to the studied elderly group has revealed good reliability and recommends further psychometric property studies to confirm the SPPB validity to the Brazilian elderly population
dc.descriptionMestrado
dc.descriptionGerontologia
dc.descriptionMestre em Gerontologia
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectIdosos
dc.subjectAptidão física
dc.subjectAvaliação funcional
dc.subjectIncapacidade
dc.subjectConfiabilidade
dc.subjectComparação transcultural
dc.subjectElderly
dc.subjectPhysical performance
dc.subjectFunctional evaluation
dc.subjectDisability
dc.subjectReliability
dc.subjectCross-cultural comparison
dc.titleVersão brasileira da Short Physical Performance Battery SPPB : adaptação cultural e estudo da confiabilidade
dc.titleBrazilian version of the Short Physical Performance Battery - SPPB: cross-cultural adaptation and reliability study
dc.typeTesis


Este ítem pertenece a la siguiente institución