Distributed generators performance during short-circuits considering fault ride-through requirements

dc.creatorSilva, Rafael Schincariol da
dc.date2012
dc.date2012-03-08T00:00:00Z
dc.date2017-04-01T10:50:17Z
dc.date2017-07-13T19:48:56Z
dc.date2017-04-01T10:50:17Z
dc.date2017-07-13T19:48:56Z
dc.date.accessioned2018-03-29T03:55:14Z
dc.date.available2018-03-29T03:55:14Z
dc.identifierSILVA, Rafael Schincariol da. Desempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = Distributed generators performance during short-circuits considering fault ride-through requirements. 2012. 136 p. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000874637>. Acesso em: 1 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/259990
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1338217
dc.descriptionOrientador: Walmir de Freitas Filho
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação
dc.descriptionResumo: O aumento da penetração de geradores em redes de distribuição de energia elétrica além de diversificar a matriz elétrica proporciona benefícios técnicos e econômicos. Contudo, também levanta preocupações relativas à confiabilidade no suprimento de energia elétrica. Para plantas eólicas conectadas na média e alta tensão são estabelecidos requisitos de "Fault Ride-Through" que determinam que os geradores devem permanecer conectados à rede durante perturbações com afundamentos de tensão e, em alguns casos, fornecer reativos para o reestabelecimento da tensão terminal. Porém, implementar tais requisitos para geradores na baixa tensão não é trivial. Na ocorrência de grandes perturbações os geradores distribuídos devem obrigatoriamente ser desconectados em casos de ilhamento, caso contrário a segurança de pessoas e equipamentos é colocada em risco e a qualidade de energia fornecida não é garantida. Ainda, durante curtos-circuitos os geradores contribuem para ao aumento das correntes de falta e os esquemas de proteção podem sofrer impactos na seletividade e coordenação. Por isso, para atender o requisito de "Fault Ride- Through" seria necessário além de manter os geradores conectados rever os esquemas de proteção de sobrecorrente, sendo necessários estudos dos impactos desta iniciativa e a análise do comportamento dos principais tipos de geradores distribuídos na ocorrência de curtos-circuitos. Nesta dissertação de mestrado, uma rede de distribuição com geradores distribuídos foi analisada através do estudo de sucessivas simulações de transitórios eletromagnéticos. O comportamento de três tipos de geradores distribuídos na ocorrência de curtos-circuitos foi investigado por meio de estudos de estabilidade, da análise das características de afundamentos de tensão e do suporte de reativos. Os geradores síncronos se mostraram com maior capacidade de suportarem faltas temporárias na rede. Os impactos do aumento das correntes de falta nas proteções contra sobrecorrente e da não desconexão do gerador do sistema ilhado também foram analisados. Os resultados mostraram que a presença de geradores distribuídos pode causar problemas na seletividade e na coordenação da proteção, alem de deteriorar o comportamento transitório de geradores ilhados
dc.descriptionAbstract: The increase of distributed generation penetration in distribution systems not only helps to diversify the electrical matrix but also brings both technical and economic benefits. Yet, it also raises worries related to energy supply reliability. For wind power plants into the medium and high voltage networks there are the grid codes for "Fault Ride-Through" which stands that wind generators ought to ride a fault with voltage sag and, in some cases, provide reactive power for the terminal voltage restoration. However, implementing such requisites for low voltage connected generators is not a trivial task, as under great perturbations the distributed generators are required to be disconnected from the grid if an islanding situation occurs. Otherwise, people and equipment security would be at risk and the quality of the supplied power cannot be guaranteed. Besides, during short-circuits generators contribute to the increased fault currents along the grid and because of that the protection schemes should experience loss of selectivity and coordination. So, meeting the fault ride-through requirement demand a review of the anti-islanding schemes in order to permit generator islanding, as well as review the protection schemes to guarantee selectivity and coordination. Therefore, studies about the impacts of this initiative are necessary as well as the main generators behavior analysis under short-circuits. In this dissertation, a distribution network was analyzed through successive electromagnetic transient simulations. The behavior of three types of distributed generators under shortcircuits was investigated by stability studies, voltage sag characteristics and reactive power support. Synchronous generators showed to present the best capability to ride through temporary faults on the grid. The impacts on overcurrent protection of increased shortcircuit currents due to the distributed generators and impacts of not disconnecting the generators during islanding situations were also analyzed. The outcomes showed that keeping distributed generators connected might lead to problems on the protection selectivity and coordination and deteriorate the transient behavior of generators
dc.descriptionMestrado
dc.descriptionEnergia Eletrica
dc.descriptionMestre em Engenharia Elétrica
dc.format136 p. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectGeração distribuída de energia elétrica
dc.subjectCurtos-circuitos
dc.subjectSistemas de energia elétrica - Proteção
dc.subjectSistemas de energia elétrica - Estabilidade
dc.subjectDistributed generation of electricity
dc.subjectShort-circuit
dc.subjectElectric power systems - Protection
dc.subjectElectric power systems - Stability
dc.titleDesempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = Distributed generators performance during short-circuits considering fault ride-through requirements
dc.titleDistributed generators performance during short-circuits considering fault ride-through requirements
dc.typeTesis