Leak detection pipes by frequency response method and reflections high frequency pulses

dc.creatorPalhares, Juliana Barbosa
dc.date2005
dc.date2005-08-25T00:00:00Z
dc.date2017-03-28T20:36:43Z
dc.date2017-06-09T20:39:17Z
dc.date2017-03-28T20:36:43Z
dc.date2017-06-09T20:39:17Z
dc.date.accessioned2018-03-29T02:26:02Z
dc.date.available2018-03-29T02:26:02Z
dc.identifier(Broch.)
dc.identifierPALHARES, Juliana Barbosa. Detecção de fugas em tubulações atraves do metodo de resposta em frequencia e reflexões de pulsos de alta frequencia. 2005. 126p. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Campinas, SP. Disponível em: <http://libdigi.unicamp.br/document/?code=vtls000377035>. Acesso em: 28 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/258176
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1315855
dc.descriptionOrientador: Edevar Luvizotto Junior
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo
dc.descriptionResumo: Nos sistemas de transporte de fluido líquido, têm-se a preocupação em combater às fugas ou vazamentos. Dessa fonna, este trabalho tem como objetivo aperfeiçoar o método de detecção de fugas em tubulações pelo método de resposta nos domínios fteqüência e tempo, utilizando como ferramentas matemáticas o Método da Matriz Transferência / Resposta em Freqüência e o Método das Características / Transfonnada Rápida de Fourier, sendo demonstradas as vantagens e desvantagens de cada método. E, como contribuição original, propõe um método de detecção de fugas através da análise de pulso de Alta Freqüência, localizando as fugas através da detenninação do tempo que um pulso emitido pela válvula leva para percorrer toda a tubulação e retomar à esta, denominado como Pulso Refletido
dc.descriptionAbstract: In liquid fluid transport systems, there is a concem about avoiding leaks. Thus, this work has as objective to improve the leak detection method in pipes by úequency and time domains response method, being used as mathematical tools the method ofTransfer-Matrix / by úequency response and the Method of Characteristics / the Fast Fourier Transform, being demonstrated the advantages and disadvantages of each method. And, as new contribution, propose a leak detection method through the analysis of high frequency pulse, detecting the leaks through determination of time that a pulse produced by the valve takes to go through all pipe and come back, is denominated as a reflected pulse
dc.descriptionMestrado
dc.descriptionRecursos Hidricos
dc.descriptionMestre em Engenharia Civil
dc.format126p. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectTeoria dos sistemas dinâmicos
dc.subjectÁgua - Tubulação
dc.subjectSistemas não lineares
dc.subjectDetectores de vazamento
dc.subjectAnálise no dominio do tempo
dc.subjectResposta em frequência
dc.subjectDynamical systems
dc.subjectWater leakage
dc.subjectNonlinear systems
dc.subjectLeak detectors
dc.subjectTime domain analysis
dc.subjectFrequency response
dc.subjectLaplace, transform of
dc.subjectPipelines
dc.titleDetecção de fugas em tubulações atraves do metodo de resposta em frequencia e reflexões de pulsos de alta frequencia