Artículos de revistas
Evaluation Of Osteotomy Fixation Changing The Number, The Extension And The Location Of The Plates.
Registro en:
The British Journal Of Oral & Maxillofacial Surgery. v. 44, n. 5, p. 377-81, 2006-Oct.
0266-4356
10.1016/j.bjoms.2005.08.009
16263196
Autor
Trivellato, Alexandre Elias
Passeri, Luis Augusto
Institución
Resumen
We used a two-dimensional model that simulated a fractured human mandible to study the extent of load resistance of different plates. We studied 49 bovine ribs in seven groups using varying number (1 or 2), lengths of plates (4 or 6-holes), and location (near the lower or upper border). The number and location of plates had a greater effect on resistance to load than length of plates. The best mean resistance values were achieved by a combination of two parallel plates secured near the lower and upper borders, followed by single plates secured near the upper border. The lowest values were with single plates secured close to the lower border. 44 377-81