dc.creatorBIGAZZI, G
dc.creatorHADLER, JC
dc.creatorCESAR, MK
dc.creatorARAYA, AMO
dc.date1995
dc.dateAPR
dc.date2014-12-16T11:34:15Z
dc.date2015-11-26T17:59:51Z
dc.date2014-12-16T11:34:15Z
dc.date2015-11-26T17:59:51Z
dc.date.accessioned2018-03-29T00:42:18Z
dc.date.available2018-03-29T00:42:18Z
dc.identifierRadiation Measurements. Pergamon-elsevier Science Ltd, v. 24, n. 2, n. 169, n. 170, 1995.
dc.identifier1350-4487
dc.identifierWOS:A1995QW87600009
dc.identifier10.1016/1350-4487(94)00105-A
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/72546
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/72546
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/72546
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1291807
dc.descriptionTwo wafers of the NIST (formerly NBS) glass standard SRM 612 recently irradiated have been compared to the pre-irradiated wafers RT3 and RT4 of glass SRM 962a, stored for 9 years at 5-degrees-C, and SRM 962, stored for 20 years at room temperature. Track area densities on internal surfaces of the glass as well as track size measurements suggest that (1) the old SRM 962 and the more recent SRM 962a calibrations are consistent and (2) annealing of the fission tracks in the pre-irradiated wafers is negligible. This last experimental result enables a direct comparison of contemporary and previous fission track age calibrations.
dc.description24
dc.description2
dc.description169
dc.description170
dc.languageen
dc.publisherPergamon-elsevier Science Ltd
dc.publisherOxford
dc.publisherInglaterra
dc.relationRadiation Measurements
dc.relationRadiat. Meas.
dc.rightsfechado
dc.rightshttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.sourceWeb of Science
dc.titleTHE THERMAL-STABILITY OF FISSION TRACKS IN THE 612-NIST GLASS STANDARD AT ROOM-TEMPERATURE
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución