dc.descriptionA method to determine six pesticides applied in soy cultivation (imazethapyr, imazaquin, metsulfuron-methyl, carboxin, chlorimuron-ethyl, and tebuconazole) using matrix solid phase dispersion (MSPD) as the extraction technique followed by a clean-up step, using a C8 co-column, and subsequent chromatographic analysis by high performance liquid chromatography diode array detection (HPLC-DAD) was developed. The validated method showed good recuperation for all pesticides (60-120%), except for metsulfuron-methyl and tebuconazole at their lowest concentration levels, and the quantification limits of the method (0.04-0.08gg-1) were below the maximum residue limits imposed by the principal regulatory agencies.
dc.description31
dc.description7
dc.description972
dc.description983
dc.languageen
dc.publisherTaylor & Francis Inc
dc.publisherPhiladelphia
dc.publisherEUA
dc.relationJournal Of Liquid Chromatography & Related Technologies
dc.relationJ. Liq. Chromatogr. Relat. Technol.
dc.rightsfechado
dc.rightshttp://journalauthors.tandf.co.uk/permissions/reusingOwnWork.asp
dc.sourceWeb of Science
dc.subjectsoy
dc.subjectmulticlass pesticides analysis
dc.subjectsample preparation
dc.subjectMSPD
dc.subjectmethod validation
dc.subjectHPLC-DAD
dc.subjectMass-spectrometry
dc.subjectExtraction Techniques
dc.subjectResidues
dc.subjectFood
dc.subjectEnvironment
dc.titleHPLC determination of pesticides in soybeans using matrix solid phase dispersion
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución