Artículos de revistas
Enterobacter cloacae sepsis outbreak in a newborn unit caused by contaminated total parenteral nutrition solution
Registro en:
American Journal Of Infection Control. Mosby-year Book Inc, v. 28, n. 3, n. 258, n. 261, 2000.
0196-6553
WOS:000087607000008
10.1067/mic.2000.105286
Autor
Tresoldi, AT
Padoveze, MC
Trabasso, P
Veiga, JFS
Marba, STM
von Nowakonski, A
Branchini, MLM
Institución
Resumen
Objective: The study aimed to investigate an outbreak caused by Enterobacter cloacae in a neonate intensive care unit. Design: A descriptive study of an outbreak of sepsis in high-risk neonates was used. Setting: The study was set in a tertiary care university teaching hospital. Patients: The patients were 11 neonates infected with Enterobacter cloacae whose symptoms and signs of sepsis developed during a 16-hour period. All but one neonate received parenteral nutrition. Isolates from blood cultures, in-use parenteral nutrition solutions, and control aliquots of parenteral nutrition solution were typed by pulsed-field gel electrophoresis. Results: Enterobacter cloacae was found in the refrigerated aliquots of parenteral nutrition solution, in blood cultures from infected newborns, and from in-use parenteral nutrition solutions. All these strains of Enterobacter cloacae had the same antibiotic susceptibility pattern and the same genomic DNA profile. The strain isolated from the one patient who did not receive parenteral nutrition presented a different susceptibility profile and genotype. Conclusion: The source of the nosocomial sepsis was the parenteral nutrition solution in 10 neonates. This contamination apparently occurred during preparation of the parenteral solution. 28 3 258 261