Artículos de revistas
Models of liquid storage tanks
Registro en:
Energy. Pergamon-elsevier Science Ltd, v. 22, n. 8, n. 805, n. 815, 1997.
0360-5442
WOS:A1997XB34500008
10.1016/S0360-5442(96)00172-7
Autor
Ismail, KAR
Leal, JFB
Zanardi, MA
Institución
Resumen
We present the results of a comparative study on thermally stratified tanks for hot storage. A two-dimensional model is employed. A numerical solution was obtained using the control-volume technique due to Patankar. The two-dimensional model was simplified for the pure conduction case. Results from the two models were compared with each other and with available numerical and experimental results. (C) 1997 Elsevier Science Ltd. 22 8 805 815