We present the waveform digitiser used in the Double Chooz experiment. We describe the hardware and the custom-built firmware specifically developed for the experiment. The performance of the device is tested with regards to digitising low light level signals from photomultiplier tubes and measuring pulse charge. This highlights the role of quantisation effects and leads to some general recommendations on the design and use of waveform digitisers.© 2013 IOP Publishing Ltd and Sissa Medialab srl. 8 8
Abe, Y., Indication for the disappearance of reactor electron antineutrinos in the Double CHOOZ experiment (2012) Phys. Rev. Lett., 108, p. 131801. , 10.1103/PhysRevLett.108.131801 Abe, Y., Reactor electron antineutrino disappearance in the Double CHOOZ experiment (2012) Phys. Rev. D, 86, p. 052008. , 10.1103/PhysRevD.86.052008 0556-2821 Aberle, C., Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection (2012) JINST, 7 (6), p. 06008. , 1748-0221 P06008 Corporation, H., Large Photocathode Area Photomulitplier Tubes Bauer, C., Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment (2011) JINST, 6 (6), p. 06008. , 1748-0221 P06008 Matsubara, T., Evaluation of 400 low background 10-in. Photo-multiplier tubes for the Double CHOOZ experiment (2012) Nucl. Instrum. Meth. A, 661, p. 16. , 10.1016/j.nima.2011.09.023 0168-9002 Zbiri, K., Note on Drexel Tests of the IMB R1408 PMTs Used in the Inner Veto of Both Far and Near Detectors of the Double CHOOZ Experiment Akiri, T., (2010) Test des Flash-ADCs, Optimisation de la Conception du Détecteur et Développement d'Un Nouveau Concept de Reconstruction Spatiale dans l'Expérience de Neutrino Double Chooz Pour la Mesure de l'Angle de Mélange θ13 Network Power, E., MVME3100 Data Sheet V1721 Data Sheet Acciarri, R., Tests of PMT Signal Read-out in a Liquid Argon Dark Matter Detector with a New Fast Waveform Digitizer (2012) JINST, 7 (7), p. 07003. , 1748-0221 P07003 Lombard, F.J., Martin, F., Statistics of Electron Multiplication (1961) Rev. Sci. Instrum., 32 (2), p. 200. , 10.1063/1.1717310 0034-6748 Kester, W., Testing Data Converters, Section 5.2: Testing ADCs INL/DNL Measurements for High-Speed Analog-to-Digital Converters (ADCs), , http://www.maximintegrated.com/app-notes/index.mvp/id/283, Tutorial 283 Semiconductor, N., ADC08D500 Data Sheet Widrow, B., Statistical Theory of Quantization (1996) IEEE Trans. Instrum. Meas., 45 (2), p. 353. , 10.1109/19.492748 0018-9456 Widrow, B., Kollar, I., (2008) Quantization Noise: Roundoff Error in Digital Computation, Signal Processing, Control, and Communications, , 10.1017/CBO9780511754661 Carbone, P., Petri, D., Mean value and variance of noisy quantized data (1998) Measurement, 23 (3), p. 131. , 10.1016/S0263-2241(98)00018-9 0263-2241