dc.creator | da Silva-Neto J.P. | |
dc.creator | Pimentel M.J. | |
dc.creator | das Neves F.D. | |
dc.creator | Consani R.L.X. | |
dc.creator | dos Santos M.B.F. | |
dc.date | 2014 | |
dc.date | 2015-06-25T17:54:26Z | |
dc.date | 2015-11-26T14:33:32Z | |
dc.date | 2015-06-25T17:54:26Z | |
dc.date | 2015-11-26T14:33:32Z | |
dc.date.accessioned | 2018-03-28T21:36:56Z | |
dc.date.available | 2018-03-28T21:36:56Z | |
dc.identifier | | |
dc.identifier | Brazilian Oral Research. , v. 28, n. 1, p. 67 - 73, 2014. | |
dc.identifier | 18068324 | |
dc.identifier | 10.1590/S1806-83242013005000028 | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84891056246&partnerID=40&md5=bac774d40cee2af34f9049c703c1737d | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/86680 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/86680 | |
dc.identifier | 2-s2.0-84891056246 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1247883 | |
dc.description | This study's aims was to evaluate the stress distribution in a mandibular implant-supported prosthesis and peri-implant bone considering implant quantity, diameter and position using linear 3-D finite element analysis. Models of an anterior jaw comprised 4 groups according to implant quantity, diameter, and position: control group C, 5 regular implants; R, 3 regular implants; W, 3 wide implants; and DTR, 3 regular implants with the distal ones tilted 30° distally. The cantilever was loaded with an axial load of 50 N. Data was evaluated using von Mises stress on implants and maximum principal stress and microstrain on the bone. The W group showed the lowest value of maximum principal stress in peri-implant bone of the loaded side (4.64 MPa) when compared to C (5.27 MPa), DTR (5.94 MPa), and R (11.12 MPa). Lower stress values in the loaded implants were observed in the experimental groups when compared to the C group. However, the unloaded implants presented opposite results. All the screws of the W group presented lower stress values when compared to the C group. However, the R and DTR groups presented an increase in stress values with the exception of the loaded screw. A reduction in the number of implants associated with wider implants reduced the stress in the bone and prosthetic components. | |
dc.description | 28 | |
dc.description | 1 | |
dc.description | 67 | |
dc.description | 73 | |
dc.description | Branemark, P.I., Svensson, B., van Steenberghe, D., Ten-year survival rates of fixed prostheses on four or six implants ad modum Branemark in full edentulism (1995) Clin Oral Implants Res., 6 (4), pp. 227-231. , Dec | |
dc.description | Mendonca, D.B., Prado, M.M., Mendes, F.A., Borges, T.F., Mendonca, G., Prado, C.J., Comparison of masticatory function between subjects with three types of dentition (2009) Int J Prosthodont., 22 (4), pp. 399-404. , Jul-Aug | |
dc.description | Branemark, P.I., Engstrand, P., Ohrnell, L.O., Grondahl, K., Nilsson, P., Hagberg, K., Branemark Novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study (1999) Clin Implant Dent Relat Res., 1 (1), pp. 2-16 | |
dc.description | Begg, T., Geerts, G.A., Gryzagoridis, J., Stress patterns around distal angled implants in the all-on-four concept configuration (2009) Int J Oral Maxillofac Implants., 24 (4), pp. 663-671. , Jul-Aug | |
dc.description | Takahashi, T., Shimamura, I., Sakurai, K., Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept (2010) J Prosthodont Res., 54 (4), pp. 179-184. , Oct | |
dc.description | Kim, K.S., Kim, Y.L., Bae, J.M., Cho, H.W., Biomechanical comparison of axial and tilted implants for mandibular full-arch fixed prostheses (2011) Int J Oral Maxillofac Implants., 26 (5), pp. 976-984. , Sep-Oct | |
dc.description | Fazi, G., Tellini, S., Vangi, D., Branchi, R., Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis (2011) Int J Oral Maxillofac Implants., 26 (4), pp. 752-759. , Jul-Aug | |
dc.description | Hatano, N., Yamaguchi, M., Yaita, T., Ishibashi, T., Sennerby, L., New approach for immediate prosthetic rehabilitation of the edentulous mandible with three implants: a retrospective study (2011) Clin Oral Implants Res., 22 (11), pp. 1265-1269. , Nov | |
dc.description | Rivaldo, E.G., Montagner, A., Nary, H., da Fontoura Frasca, L.C., Branemark, P.I., Assessment of rehabilitation in edentulous patients treated with an immediately loaded complete fixed mandibular prosthesis supported by three implants (2012) Int J Oral Maxillofac Implants., 27 (3), pp. 695-702. , May-Jun | |
dc.description | Engstrand, P., Grondahl, K., Ohrnell, L.O., Nilsson, P., Nannmark, U., Branemark, P.I., Prospective follow-up study of 95 patients with edentulous mandibles treated according to the Branemark Novum concept (2003) Clin Implant Dent Relat Res., 5 (1), pp. 3-10. , May | |
dc.description | Krekmanov, L., Kahn, M., Rangert, B., Lindstrom, H., Tilting of posterior mandibular and maxillary implants for improved prosthesis support (2000) Int J Oral Maxillofac Implants., 15 (3), pp. 405-414. , May-Jun | |
dc.description | Bevilacqua, M., Tealdo, T., Pera, F., Menini, M., Mossolov, A., Drago, C., Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths (2008) Int J Prosthodont., 21 (6), pp. 539-542. , Nov-Dec | |
dc.description | Dos Santos, M.B., Bacchi, A., Consani, R.L., Mesquita, M.F., Influence of thickness and area of reline on the stress distribution in peri-implant bone during the healing period: a three-dimensional finite element analysis (2012) Gen Dent., 60 (4), pp. e231-6. , Jul-Aug | |
dc.description | Dos Santos, M.B., Consani, R.L., Mesquita, M.F., Influence of different soft liners on stress distribution in peri-implant bone tissue during healing period. A 3-D finite element analysis (2011) J Oral Implantol, , Jul 18. Epub ahead of print | |
dc.description | Dos Santos, M.B., Silva Neto, J.P., Consani, R.L., Mesquita, M.F., Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps (2011) J Oral Rehabil., 38 (9), pp. 691-696. , Sep | |
dc.description | Spazzin, A.O., Dos Santos, M.B., Correr-Sobrinho, L., Consani, R.L., Mesquita, M.F., Effects of horizontal misfit and bar framework material on the stress distribution of an overdenture-retaining bar system: a 3D finite element analysis (2011) J Prosthodont., 20 (7), pp. 517-522. , Oct | |
dc.description | Branemark, P.I., The Branemark Novum Protocol for same-day teeth. A global perspective (2000), p. 166. , Berlin: QuintessenceDuyck, J., Van Oosterwyck, H., Vander Sloten, J., De Cooman, M., Puers, R., Naert, I., Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study (2000) Clin Oral Implants Res., 11 (5), pp. 465-475. , Oct | |
dc.description | Himmlova, L., Dostalova, T., Kacovsky, A., Konvickova, S., Influence of implant length and diameter on stress distribution: a finite element analysis (2004) J Prosthet Dent., 91 (1), pp. 20-25. , Jan | |
dc.description | Mahon, J.M., Norling, B.K., Phoenix, R.D., Effect of varying fixture width on stress and strain distribution associated with an implant stack system (2000) Implant Dent., 9 (4), pp. 310-320. , Winter | |
dc.description | Renouard, F., Nisand, D., Impact of implant length and diameter on survival rates (2006) Clin Oral Implants Res, 17 (SUPPL. 2), pp. 35-51. , Oct | |
dc.description | Friberg, B., Ekestubbe, A., Sennerby, L., Clinical outcome of Branemark System implants of various diameters: a retrospective study (2002) Int J Oral Maxillofac Implants., 17 (5), pp. 671-677. , Sep-Oct | |
dc.description | Wiskott, H.W., Belser, U.C., Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone (1999) Clin Oral Implants Res., 10 (6), pp. 429-444. , Dec | |
dc.description | Huang, H.L., Chang, C.H., Hsu, J.T., Fallgatter, A.M., Ko, C.C., Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis (2007) Int J Oral Maxillofac Implants., 22 (4), pp. 551-562. , Jul-Aug | |
dc.language | en | |
dc.publisher | | |
dc.relation | Brazilian Oral Research | |
dc.rights | aberto | |
dc.source | Scopus | |
dc.title | Stress Analysis Of Different Configurations Of 3 Implants To Support A Fixed Prosthesis In An Edentulous Jaw | |
dc.type | Artículos de revistas | |