Fitting Monocurve And Bicurve (soper-mcguire Design) Rigid Gas-permeable Contact Lenses In Keratoconus Patients: A Prospective Randomized Comparative Clinical Trial [avaliação Comparativa Da Adaptação De Lentes De Contato Rígidas Gás-permeáveis Monocurvas E Bicurvas (desenho Soper-mcguire) Em Pacientes Portadores De Ceratocone: Um Estudo Prospectivo E Randomizado]
Registro en:
Arquivos Brasileiros De Oftalmologia. , v. 71, n. 3, p. 328 - 336, 2008.
42749
2-s2.0-62149113359
Autor
Coral-Ghanem C.
Alves M.R.
Institución
Resumen
Purpose: To evaluate the clinical performance of Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lens fitting in patients with keratoconus. Methods: A prospective and randomized comparative clinical trial was conducted with a minimum follow-up of six months in two groups of 63 patients. One group was fitted with Monocurve contact lenses and the other with Bicurve Soper-McGuire design. Study variables included fluoresceinic pattern of lens-to-cornea fitting relationship, location and morphology of the cone, presence and degree of punctate keratitis and other corneal surface alterations, topographic changes, visual acuity for distance corrected with contact lenses and survival analysis for remaining with the same contact lens design during the study. Results: During the follow-up there was a decrease in the number of eyes with advanced and central cones fitted with Monocurve lenses, and an increase in those fitted with Soper-McGuire design. In the Monocurve group, a flattening of both the steepest and the flattest keratometric curve was observed. In the Soper-McGuire group, a steepening of the flattest keratometric curve and a flattening of the steepest keratometric curve were observed. There was a decrease in best-corrected visual acuity with contact lens in the Monocurve group. Survival analysis for the Monocurve lens was 60.32% and for the Soper-McGuire was 71.43% at a mean follow-up of six months. Conclusions: This study showed that due to the changes observed in corneal topography, the same contact lens design did not provide an ideal fitting for all patients during the follow-up period. The Soper-McGuire lenses had a better performance than the Monocurve lenses in advanced and central keratoconus. 71 3 328 336 Krachmer, J.H., Feder, R.S., Belin, M.W., Keratoconus and related noninflammatory corneal thinning disorders (1984) Surv Ophthalmol, 28 (4), pp. 293-322 Rabinowitz, Y.S., Keratoconus (1998) Surv Ophthalmol, 42 (4), pp. 297-319. , Review Griffiths, M., Zahner, K., Collins, M., Carney, L., Masking of irregular corneal topography with contact lenses (1998) CLAO J, 24 (2), pp. 76-81 Buxton, J.N., Contact lenses in keratoconus (1978) Contact Intraocul Lens Med J, 4, pp. 74-85 Carney, L.G., Contact lens correction of visual loss in keratoconus (1982) Acta Ophthalmol (Copenh), 60 (5), pp. 795-802 Buxton, J.N., Keattes, R.H., Hoeffle, F.B., The contact lens correction of keratoconus (1984) The CLAO guide to basic science and clinical practice, p. 55. , Dabezies OH Jr. Orlando: Grune & Stratton, 1-55.14 Belin, M.W., (1988) Optical and surgical correction of keratoconus - Focal points: 1988. Clinical Module for Ophthalmologists, , San Francisco: American Academy of Ophthalmology Kastl, P.R., Donzis, P.B., Cole H.P. III, Rice, J., Baldone, J.A., A 20-year retrospective study of the use of contact lenses in keratoconus (1987) CLAO J, 13 (2), pp. 102-104 Smiddy, W.E., Hamburg, T.R., Kracher, G.P., Stark, W.J., Keratoconus. Contact lens or keratoplasty? (1988) Ophthalmology, 95 (4), pp. 487-492 Leça, R.G., Fukushima, N., Gonzaga, R., Lipener, C., Zamboni, F., Lewinsky, R., Uras, R., Estudo clínico da adaptação de lentes de contato no ceratocone (1995) Arq Bras Oftalmol, 58 (3), pp. 149-151 Ghanem, V.C., Coral-Ghanem, C., Ghanem, R.C., Larinho, C., Ceratocone: correlação entre grau evolutivo e padrão topográfico com o tipo de lente de contato adaptada (2003) Arq Bras Oftalmol, 66 (2), pp. 129-135 Garcia-Lledo, M., Feinbaum, C., Alio, J.L., Contact lens fitting in keratoconus (2006) Compr Ophthalmol Update, 7 (2), pp. 47-52 Lass, J.H., Lembach, R.G., Park, S.B., Hom, D.L., Fritz, M.E., Svilar, G.M., Clinical management of keratoconus. A multicenter analysis (1990) Ophthalmology, 97 (4), pp. 433-445 Benett, E.S., Keratoconus (1986) Rigid gaspermeable contact lenses, pp. 297-344. , Bennett ES, Grohe RM, editors. New York: Professional Press Books Dana, M.R., Putz, J.L., Viana, M.A., Sugar, J., McMahon, T.T., Contact lens failure in keratoconus management (1992) Ophthalmology, 99 (8), pp. 1187-1192. , Comment in: Ophthalmology. 1992;99(12):1752-3. Ophthalmology. 1993;100(2):147-8 Lim, N., Vogt, U., Characteristics and functional outcomes of 130 patients with keratoconus attending a specialist contact lens clinic (2002) Eye, 16 (1), pp. 54-59 Mannis, M.J., Zadnik, K., Contact lens fitting in keratoconus (1989) CLAO J, 15 (4), pp. 282-289. , Review Mandell, R.B., Contemporary management of keratoconus (1997) Int Contact Lens Clin, 24 (2), pp. 43-58 Lee, J.L., Kim, M.K., Clinical performance and fitting characteristics with a multicurve lens for keratoconus (2004) Eye Contact Lens, 30 (1), pp. 20-24 Soper, J.W., Jarrett, A., Results of a systematic approach to fitting keratoconus and corneal transplants (1972) Contact Lens Med Bull, 5, pp. 50-59 Crews, M.J., Driebe W.T., Jr., Stern, G.A., The clinical management of keratoconus: a 6 year retrospective study (1994) CLAO J, 20 (3), pp. 194-197 Szczotka, L.B., Barr, J.T., Zadnik, K., A summary of the findings from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. CLEK Study Group (2001) Optometry, 72 (9), pp. 574-584 Chiquiar Arias, V., Liberatore, J.C., Voss, E.H., Chiquiar Arias, M., A new technique of fitting contact lenses on keratoconus (1959) Contacto, 3, pp. 393-415 Barr, J.T., Zadnik, K., Wilson, B.S., Edrington, T.B., Everett, D.F., Fink, B.A., Factors associated with corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study (2000) Cornea, 19 (4), pp. 501-507 Korb, D.R., Finnemore, V.M., Herman, J.P., Apical changes and scarring in keratoconus as related to contact lens fitting techniques (1982) J Am Optom Assoc, 53 (3), pp. 199-205 Barr, J.T., Yackels, T., Corneal scarring in keratoconus - measurements and influence on visual acuity (1991) Int Contact Lens Clin, 22 (7), pp. 173-175 Zadnik, K., Barr, J.T., Steger-May, K., Edrington, T.B., McMahon, T.T., Gordon, M.O., Comparison of flat and steep rigid contact lens fitting methods in keratoconus (2005) Optom Vis Sci, 82 (12), pp. 1014-1021. , The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group Hartstein, J., Becker, B., Research into the pathogenesis of keratoconus. A new syndrome: low ocular rigidity, contact lenses, and keratoconus (1970) Arch Ophthalmol, 84 (6), pp. 728-729 Edmund, C., Corneal elasticity and ocular rigidity in normal and keratoconic eyes (1988) Acta Ophthalmol (Copenh), 66 (2), pp. 134-140 Moon, J.W., Shin, K.C., Lee, H.J., Wee, W.R., Lee, J.H., Kim, M.K., The effect of contact lens wear on the ocular surface changes in keratoconus (2006) Eye Contact Lens, 32 (2), pp. 96-101 Romanchuk, K.G., Fluorescein. Physiochemical factors affecting its fluorescence (1982) Surv Ophthalmol, 26 (5), pp. 269-283 Knoll, H.A., Conway, H.D., Analysis of blink-induced vertical motion of contact lenses (1987) Am J Optom Physiol Opt, 64 (2), pp. 153-155 Mandell, R.B., Fitting methods and philosophies (1988) Contact lens practice, pp. 226-243. , Mandell RB. Springfield, IL: Thomas Craig, E.L., Fluorescein and other dues (1994) Havener's ocular pharmalogogy, pp. 451-467. , Mauger TF, Craig EL, editors. 6a ed. St Louis: Mosby Fink, B.A., Barr, J.T., Edrington, T.B., Pierce, G.E., Schechtman, K.B., Rah, M.J., Flom, R., Zadnik, K., Collaborative Longitudinal Evaluation of Keratoconus. A comparison of two methods of evaluating corneato-contact lens base curve fluorescein patterns in keratoconus (2001) Optom Vis Sci, 78 (8), pp. 589-598. , CLEK Study Group Maguire, L.J., Bourne, W.M., Corneal topography of early keratoconus (1989) Am J Ophthalmol, 108 (2), pp. 107-112 Wilson, S.E., Lin, D.T., Klyce, S.D., Corneal topography of keratoconus (1991) Cornea, 10 (1), pp. 2-8 Szczotka, L.B., Rabinowitz, Y.S., Yang, H., Influence of contact lens wear on the corneal topography of keratoconus (1996) CLAO J, 22 (4), pp. 270-273 Carney, L.G., Corneal topography changes during contact lens wear (1974) Contact Lens J, 3 (1), pp. 5-16 Carney, L.G., The basis for corneal shape change during contact lens wear (1975) Am J Optom Physiol Opt, 52 (7), pp. 445-454 Wilson, S.E., Lin, D.T., Klyce, S.D., Reidy, J.J., Insler, M.S., Topographic changes in contact lens-induced corneal warpage (1990) Ophthalmology, 97 (6), pp. 734-744 Maeda, N., Klyce, S.D., Hamano, H., Alteration of corneal asphericity in rigid gas permeable contact lens induced warpage (1994) CLAO J, 20 (1), pp. 27-31 Zadnik, K., Mutti, D.O., Contact lens fitting relation and visual acuity in keratoconus (1987) Am J Optom Physiol Opt, 64 (9), pp. 698-702 Xie, P.Y., Wang, D., Yang, L.N., Zhou, W.J., The evaluation of visual quality in keratoconus eyes corrected by rigid gas-permeable contact lens (2005) Zhonghua Yan Ke Za Zhi, 41 (12), pp. 1086-1091. , Chineese Jaworski, P., Wygledowska-Promienska, D., Gierek-Ciaciura, S., Application of duo-systems (piggy back) in correction of keratoconus (2004) Klin Oczna, 106 (4-5), pp. 629-632. , Polish