Artículos de revistas
Grain Size Distribution In Granular Cu100-xcox Through Anhysteretic Magnetisation Curve Analysis
Registro en:
Journal Of Magnetism And Magnetic Materials. , v. 157-158, n. , p. 319 - 320, 1996.
3048853
10.1016/0304-8853(95)01008-4
2-s2.0-0030563823
Autor
Allia P.
Ghigo F.
Knobel M.
Tiberto P.
Vinai F.
Institución
Resumen
The magnetisation of melt-spun, granular Cu100-xCox (x = 5, 15) was measured at room temperature on as-cast and Joule-heated samples. The particle size distribution and the volume density of Co clusters were obtained by fitting the anhysteretic magnetisation curves with four Langevin functions, corresponding to Co particles of definite radii. 157-158
319 320 Xiao, J.Q., Jiang, J.S., Chien, C.L., (1992) Phys. Rev. Lett., 68, p. 3749 Wecker, J., Von Helmolt, R., Schultz, L., Samwer, K., (1993) Appl. Phys. Lett., 62, p. 1985 Zhang, S., (1993) Appl. Phys. Lett., 61, p. 2759 Allia, P., Baricco, M., Tiberto, P., Vinai, F., (1993) Philos. Mag. B, 68, p. 853 (1993) Rev. Sci. Instr., 64, p. 1053 Hütten, A., Thomas, G., (1993) Ultramicroscopy, 52, p. 581