Artículos de revistas
Technical Aspects Of Coronary Sinus Catheterization Based On The Atrial Component Of The Intracavitary Electrogram And Radiological Anatomy During The Implantation Procedure Of A Biventricular Pacemaker
Registro en:
Arquivos Brasileiros De Cardiologia. , v. 86, n. 4, p. 261 - 267, 2006.
0066782X
2-s2.0-33646433991
Autor
De Souza F.S.O.
Mortati N.L.
Braile D.M.
Vieira R.W.
Rojas S.O.
Rabelo A.C.
De Souza J.M.
De Oliveira S.A.
Institución
Resumen
OBJECTIVE: To present a technical proposal based on the experience of 130 implantations using a simplified technique for coronary sinus catheterization, based on the atrial component of the intracavitary electrogram and radiological anatomy. METHODS: From October, 2001 to October, 2004, 130 biventricular pacemaker implantations were performed, using radiological anatomy and observation of the intracavitary electrogram, focusing on the atrial component. RESULTS: The implantation of the system using left ventricular pacing via coronary sinus was not possible in 8 patients. Difficulties on the cannulation of the coronary ostium were felt in 12 patients and difficulties of lead advancement through the coronary sinus were felt in 15 patients. The mean time of radioscopy utilization was 18.69 min. CONCLUSION: The implantation technique, using the atrial component morphology of the intracavitary electrogram and radiological anatomy showed to be workless, safe and effective for the cannulation of the coronary sinus ostium requesting reduced time of radioscopy. 86 4 261 267 Carvalho Filho, E.T., Curiati, J.A.E., Insuficiência cardíaca no idoso (2001) Rev Bras Med, 58, pp. 109-131 Brito Jr., H.L., Bianchi, F.N., Nascimento, L.E.P., Estimulação cardíaca artificial como tratamento dos pacientes com miocardiopatia dilatada e insuficiência cardíaca. Novos conceitos, novas técnicas e necessidades de atualizaçã o (2000) Reblampa, 13, pp. 185-193 Auricchio, A., Stellbrink, C., Sack, S., Chronic benefit as a result of pacing in congestive heart failure: Results of the PATH-CHF trials (2000) Circulation, 102, pp. 3352A Linde, C., Leclercq, C., Rex, S., Long-Term benefits of Biventricular Pacing in Congestive heart Failure: Results from the MUltisite STimulation in Cardiomyopathy (MUSTIC) Study (2002) J Am Coll Cardiol, 40, pp. 111-118 Abraham, W.T., Fisher, W.G., Smith, A.L., Cardiac resynchronization in chronic heart failure (2002) N Engl J Med, 346, pp. 1845-1853 Fatemi, M., Etienne, Y., Gilard, M., Short and long-term single-centre experience with an S-shaped unipolar lead for left ventricular pacing (2003) Europace, 5, pp. 207-211 Curnis, A., Neris, R., Mascioli, G., Left ventricular pacing lead choice base on coronary sinus venous anatomy (2000) Eur Heart J, 21 (SUPPL. J), pp. J31-J35 Kautzner, J., Riedlbauchova, L., Cihak, R., Technical aspects of implantation of LV lead for cardiac resynchronization therapy in chronic heart failure (2004) Pacing Clin Electrophysiol, 27, pp. 783-790 Purerfellner, H., Nesser, H.J., Winter, S., Transvenous left ventricular lead implantation with the EASYTRACK lead system: The European Experience (2000) Am J Cardiol, 86 (SUPPL.), pp. 157K-164K Neuzer, J., Pappone, C., Aurrichio, A., Learning curve for the first 1000 over-the-wire left ventricular transvenous lead implants-a Europe experience (2001) Eur J Heart Failure, 3 (1 SUPPL.), pp. S13 Curley, J., Lamba, S., Moulton, K., Does the availability of left heart lead and delivery system options matter for cardiac resynchronization therapy? (2002) Pacing Clin Electrophysiol, 24, p. 597 Butter, C., Gras, D., Ritter, P., Comparative prospective randomized efficacy testing of different guiding catheters for coronary sinus cannulation in heart failure patients (2003) J Interv Card Electrophysiol, 9, pp. 343-351 Walker, S., Levy, T., Rex, S., Paul, V.E., The use of a "side-wire" permanent transvenous-pacing electrode for left ventricular pacing (1999) Europace, 1, pp. 197-200 Auricchio, A., Klein, H., Tockman, B., Transvenous biventricular pacing for heart failure: Can the obstacles be overcome? (1999) Am J Cardiol, 83, pp. 136D-142D Santosky, R., Walter III, H.L., Ross, R.D., Coronary sinus ostial atresia with persistent left superior vena cava (1996) Ann Thorac Surg, 61, pp. 879-882 Gogna, A., Tan, H.T., Atresia of coronary sinus ostium with retrograde drainage via persistent left superior vena cava (2003) Ann Torca Surg, 76, pp. 2091-2092 Niebauer, M.J., Daoud, E., Williamson, B., Atrial electrogram characteristics in patients with and without atrioventricular nodal reentrant tachycardia (1995) Circulation, 156, pp. 61-69 Galvão Filho, S.S., Passagem de cabo eletrodo para estimulação cardíaca artificial provisória, orientada por monitorização endocavitária (1990) An Paul Med Cir, 117, pp. 47-53 Carneiro, E.F., A ativação do coração (1997) O Eletrocardiograma - 10 Anos Depois, , Rio de Janeiro: Cervantes Editora Ltda General Practice Notebook - A UK Medical Encyclopedia on the World Wide Web, , http://www.gpnotebook.co.uk, Warwickshire: c2004 Yee, R., Pappone, C., Maertens, S., Clinical experience with over-the-wire left ventricular pacing lead for biventricular pacing in heart failure patients: Multicenter report (2001) Can J Cardiol, (SUPPL. C), pp. 89C-288C Bergman, R.A., Afifi, A., Miyauchi, R., Coronary Sinus (1966) Illustrated Encyclopedia of Human Anatomic Variation: Opus II: Cardiovascular System: Veins: Head, Neck, and Thorax. 12 Ed., , Anson BJ. New York: McGraw-Hill Book Company Lundinghausen, M., Ohmachi, N., Boot, C., Myocardial coverage of the coronary sinus and related veins (1992) Clin Anat, 5, pp. 1-15