Artículos de revistas
Intralenticular metal foreign body: case report
Corpo estranho metálico intracristaliniano: relato de caso
Registro en:
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 69, n. 5, p. 749-751, 2006.
0004-2749
S0004-27492006000500025
10.1590/S0004-27492006000500025
Autor
Medina, Flavio Mac Cord
Pierre Filho, Paulo de Tarso Ponte
Lupinacci, Álvaro Pedroso de Carvalho
Costa, Dacio Carvalho
Torigoe, Andréa Mara Simões
Institución
Resumen
Intralenticular foreign bodies comprise about 5% to 10% of all intraocular foreign bodies and can result in serious complications. The management depends on some factors like size, location, material type and the risk of infection. We present a patient with an intralenticular metal foreign body in the left eye that, following initial treatment with topical steroid and antibiotic, underwent lens aspiration with removal of the intralenticular foreign body and insertion of a posterior chamber intraocular lens with good visual outcome. Os corpos estranhos intracristalinianos representam cerca de 5 a 10% de todos os corpos estranhos intra-oculares. A conduta depende de alguns fatores, como: tamanho, localização, tipo de material e probabilidade de infecção. Relatamos um caso de um paciente com um corpo estranho metálico intracristaliniano no olho esquerdo que, após realizar tratamento inicial com esteróide e antibiótico tópicos, submeteu-se à aspiração do cristalino, retirada do corpo estranho e implante de lente intra-ocular com bom resultado visual. 749 751