Microwave paleointensity analysis of historic lavas from Paricutín volcano, Mexico

dc.creatorGoguitchaichvili, A.
dc.creatorConte, G.
dc.creatorUrrutia.Fucugauchi, J.
dc.creatorAlva­-Valdivia, L.
dc.creatorMorales, J.
dc.creatorGonzález-Morán, T.
dc.date2012-04-17
dc.date.accessioned2018-03-16T15:55:56Z
dc.date.available2018-03-16T15:55:56Z
dc.identifierhttp://ojs.unam.mx/index.php/geofisica/article/view/40231
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1203696
dc.descriptionReportamos el estudio de paleointensidad de lavas históricas del volcán Paricutín por el método de microondas, las cuales fueron eruptadas durante el período entre 1943 y 1948. Muchas de las muestras se caracterizan por presentar gráficas ortogonales univectoriales. Los estudios de magnetismo de rocas y microscopía indican titanomagnetitas de dominio seudo sencillo como los portadores de la remanencia. La técnica de microondas se aplicó a muestras seleccionadas usando variantes al método de Thellier de Kono y Ueno (1977) y de Coe et al. (1978). Las muestras dieron resultados de paleointensidad de alta calidad técnica, no obstante mostraron alta dispersión en un mismo flujo siendo significativamente diferentes del valor esperado de 45 mT. Esto también se observó en los resultados obtenidos al aplicar el método de Thellier (Urrutia-Fucugauchi et al., 2004). Se exploraron las explicaciones a este comportamiento respecto a otros estudios en lavas históricas. La alta calidad técnica de los resultados sugiere que no hay criterios que puedan distinguir entre datos de paleointensidad  correctos y erróneos.es-ES
dc.descriptionWe report a microwave paleointensity study of historic lavas from Paricutin volcano, erupted during the period between 1943 and 1948. Most samples are characterized by uni-vectorial orthogonal plots. Rock-magnetic and microscopy studies indicate pseudo-single-domain titanomagnetites as the remanence carriers. The microwave paleointensity technique was applied to selected samples using both Kono and Ueno (1977) and Coe et al. (1978) variants of the Thellier method. The samples yielded technically high quality paleointensity results, though show high within-flow dispersion and are significantly different from the expected value of 45mT. This is also seen in results using the Thellier method (Urrutia-Fucugauchi et al., 2004). Explanations for this behaviour are explored, with reference to other historic lava studies. The technically high quality of the results suggest there is no criteria that can distinguish between correct and erroneous paleointensity data.en-US
dc.formatapplication/pdf
dc.languagespa
dc.publisherInstituto de Geofísicaes-ES
dc.relationhttp://ojs.unam.mx/index.php/geofisica/article/view/40231/36624
dc.sourceGeofísica Internacional; Vol 44, No 3 (2005)es-ES
dc.source0016-7169
dc.subjectPaleomagnetism, paleointensity, microwave technique.en-US
dc.subjectPaleomagnetismo, paleointensidad, método de microondas.es-ES
dc.titleMicrowave paleointensity analysis of historic lavas from Paricutín volcano, Mexicoen-US
dc.titleMicrowave paleointensity analysis of historic lavas from Paricutín volcano, Mexicoes-ES
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución