dc.contributor | Bravo Calderón, Manuel Estuardo | |
dc.creator | Marín Arias, Diana Monserrat | |
dc.date | 2016-06-27T14:51:42Z | |
dc.date | 2016-06-27T14:51:42Z | |
dc.date | 2016 | |
dc.date.accessioned | 2018-03-14T20:21:25Z | |
dc.date.available | 2018-03-14T20:21:25Z | |
dc.identifier | http://dspace.ucuenca.edu.ec/handle/123456789/25166 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1132402 | |
dc.description | Tradicionalmente, los ortodoncistas han realizado las mediciones dentales en los modelos de yeso, pero los avances tecnológicos permiten ahora a los ortodoncistas realizar esas mediciones en los modelos digitales. El propósito de este estudio fue comparar la fiabilidad y reproducibilidad de las medidas de los tamaños dentarios y las arcadas dentarias entre el método manual y los métodos digitales 3D obtenidos por un escáner intraoral CEREC Omnicam (Sirona Dental Systems) y dos escáneres extraorales: inEos X5 (Sirona Dental Systems) y Dental Scanner SMART (Open Technologies). Un modelo de yeso, un escaneado intraoral y dos modelos digitales con un escáner extraoral fueron realizadas para cada uno de los 20 sujetos. Las medidas de los tamaños dentarios, la distancia intercanina y la distancia intermolar de los modelos digitales se compararon con los correspondientes modelos de yeso (estándar de oro) Se utilizó el test de ANOVA para establecer la fiabilidad entre los cuatro métodos y el coeficiente de correlación intraclase fue calculado para determinar la reproducibilidad intra- e inter-examinador. Los resultados encontrados fueron que no existieron diferencias estadísticamente significativas entre las medidas hechas directamente en los modelos de yeso y los modelos digitales. Los coeficientes de correlación intraclase tanto intra- e inter-examinador fue alto y considerado bueno para los cuatro métodos de medición. CCI> 0.90. Se concluyó que las mediciones en los modelos digitales obtenidos con un escáner extraoral e intraoral son fiables y reproducibles | |
dc.description | Traditionally, orthodontists have made dental measurements on plaster models, but technological advances now allow orthodontists to make these measurements on digital models. The purpose of this study was to compare the reliability and reproducibility of measurements of tooth sizes and dental arches between manual method and 3D digital methods obtained by an intraoral scanner CEREC Omnicam (Sirona Dental Systems) and two extraoral scanners: inEos X5 (Sirona Dental Systems) and Dental Scanner SMART (Open Technologies). A plaster model, an intraoral scan and two digital models with an extraoral scanner were made for each of the 20 subjects. The measures of tooth sizes, intercanina distance and intermolar distance on the digital models were compared with the corresponding plaster models (gold standard). ANOVA was used to establish the reliability between the four methods and intraclass correlation coefficient was calculated to determine the intra- and inter-examiner reproducibility. The results were not statistically significant differences between measurements made directly on the plaster models and digital models. Intraclass correlation coefficients both intra- and inter-examiner was high and considered good for the four measurement methods ICC>0.90. It was concluded that measurements on digital models obtained with intraoral and extraoral scanners are reliable and reproducible | |
dc.description | Especialista en Ortodoncia | |
dc.description | Cuenca | |
dc.format | application/pdf | |
dc.language | spa | |
dc.relation | ODONOR;17 | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | |
dc.source | instname:Universidad de Cuenca | |
dc.source | reponame:Repositorio Digital de la Universidad de Cuenca | |
dc.subject | MODELOS DIGITALES 3D | |
dc.subject | MEDICIONES DENTARIAS | |
dc.subject | ESCANERES EXTRAORALES | |
dc.subject | ESCANERES INTRAORALES | |
dc.title | Estudio comparativo de la fiabilidad y reproducibilidad en la medición de los tamaños dentarios y las medidas de las arcadas dentarias entre registros manuales y digitales 3d obtenidos por escaneado intraoral y extraoral | |
dc.type | Tesis | |