Biomechanical in vitro evaluation of three stable internal fixation techniques used in sagittal osteotomy of the mandibular ramus: a study in sheep mandibles
(Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru, 2012-07-01)
Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating ...
In Vitro Biomechanical Evaluation of the Use of Conventional and Locking Miniplate/Screw Systems for Sagittal Split Ramus Osteotomy
(W B Saunders Co-elsevier Inc, 2010-04-01)
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical ...
Tomographic analysis of the interalveolar space and thickness of the vestibular cortical bone in the parasymphyseal region of adult human mandibles
(Springer, 2010-12-01)
Purpose the aim of this study was to determine by computed tomography (CT) the interalveolar distance on mandible relative to the canine, first and second pre-molar, and the thickness of the cortical bone in the same ...
Fresh-frozen human bone allograft in vertical ridge augmentation: clinical and tomographic evaluation of bone formation and resorption
(Springer, 2012-12-01)
The aim of the current study is to evaluate fresh-frozen human bone allografts (FHBAs) used in vertical ridge augmentation clinically and by computed tomography, and to analyze the resulting bone formation and graft ...
Healing outcomes at implants installed in grafted sites: an experimental study in dogs
(Wiley-Blackwell, 2012-03-01)
Aim: To evaluate the integration of implants installed using a surgical guide in augmented sites with autologous bone or deproteinized bovine bone mineral (DBBM) blocks, concomitantly with a collagen membrane.Material and ...
Bone Spreading and Standardized Dilation of Horizontally Resorbed Bone: Technical Considerations
(Lippincott Williams & Wilkins, 2009-04-01)
The uses of a new bone spreading technique with simultaneous implant placement are discussed. The spreading system is an alternative technique to Summers' osteotome. Specific screw designs (spreader) served to laterally ...
Screw Spreading: Technical Considerations and Case Report
(Quintessence Publishing Co Inc, 2011-04-01)
The spreading system is an alternative technique to the Summers osteotome. The crest expansion technique is a less invasive procedure in which the facial wall expands after the medullary bone is compressed against the ...
Histomorphometric evaluation of a threaded, sandblasted, acid-etched implant retrieved from a human lower jaw: A case report
(2005-09-01)
The purpose of this study was to histomorphometrically evaluate the bone-to-implant contact and bone area around a titanium implant retrieved from a human lower jaw. A screw-shaped titanium implant (sandblasted and acid-etched ...
Healing at mandibular block-grafted sites: an experimental study in dogs
(Wiley-Blackwell, 2015)