Buscar
Mostrando ítems 11-20 de 49
Sistema plate-nail para fixação de fratura de fêmur em um lobo-guará (Crysocyon brachyurus)Plate-nail system for femoral fracture fixation in a maned wolf (Crysocyon brachyurus)
(Universidade Federal do Rio Grande do Sul, 2017)
Treatment of distal fractures of the tibia
(Atha Comunicacao & Editora, 2009-01-01)
Objective: to compare the results of fibula fixation (or non fixation) in the treatment of fractures located in the distal third of the tibia, by using intramedullary nailing and bridge plate. Method: 47 fractures on 47 ...
The effect of simvastatin treatment on bone repair of femoral fracture in animal model
(Informa Healthcare, 2015)
Treatment of radius, ulna and humerus fractures with the aid of a bone morphogenetic protein in a giant anteater (Myrmecophaga tridactyla)
(Schattauer Gmbh-verlag Medizin Naturwissenschaften, 2003-01-01)
A giant anteater (Myrmecophaga tridactyla) was found with closed comminuted fractures on the fight radius and ulna and left humerus he duration of which was unknown. The animal was unable to use either of he thoracic limbs. ...
Severe fracture of the maxillary alveolar process associated with extrusive luxation and tooth avulsion: A case report
(2009-01-01)
Aim: The aim of this report is to present a case of severe fracture of the maxillary anterior alveolar process with substantial bone dislodgement associated with extrusive tooth luxation and avulsion. Background: Dentoalveolar ...
Use of an osteoconductive compound as an aid in the management of a maxillary fracture in a boa constrictor
(Canadian Vet Med Assoc, 2011-03-01)
A boa constrictor was presented with a short oblique compound fracture of the rostral third of the right maxilla. The fracture was reduced and biomaterial was placed around the fracture. A computed tomography scan at 1.5 ...
Histomorphometric evaluation of a threaded, sandblasted, acid-etched implant retrieved from a human lower jaw: A case report
(2005-09-01)
The purpose of this study was to histomorphometrically evaluate the bone-to-implant contact and bone area around a titanium implant retrieved from a human lower jaw. A screw-shaped titanium implant (sandblasted and acid-etched ...
Tratamento das fraturas do terço distal da tíbia: fixar ou não a fíbula?
(Sociedade Brasileira de Ortopedia e Traumatologia, 2011-01-01)
OBJECTIVE: To compare the results of fibula fixation (or not fixation) in the treatment of fractures located in the distal third part of the tibia, by using intramedullary nailing and bridge plate. METHOD: 47 fractures in ...
Biomechanical effect of one session of low-level laser on the bone-titanium implant interface
(2013-01-01)
Low-level laser (LLL) has been used on peri-implant tissues for accelerating bone formation. However, the effect of one session of LLL in the strength of bone-implant interface during early healing process remains unclear. ...