Buscar
Mostrando ítems 1-10 de 91
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2010-01-01)
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and ...
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2010-01-01)
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and ...
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2013)
Human non-decalcified histology of three dental implants 45 months under function-a case report
(Springer, 2019-09-25)
Background Fracture of an implant is a quite rare event but represents an important opportunity to evaluate the peri-implant bone tissue response to implant overload in human beings. This study aimed to evaluate bone tissue ...
Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections
(2013-03-01)
Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic ...
Photoelastic comparison of single tooth implant-abutment-bone of platform switching vs conventional implant designs
(2011-03-01)
Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of ...
Photoelastic comparison of single tooth implant-abutment-bone of platform switching vs conventional implant designs
(2011-03-01)
Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of ...
Reaction of rat connective tissue to implanted dentin tubes filled with a white mineral trioxide aggregate.
(2002-03-01)
The purpose of this paper was to study the reaction of rat subcutaneous connective tissue to the implantation of dentin tubes filled with white mineral trioxide aggregate (MTA), a material that will be marketed. The tubes ...
Reaction of rat connective tissue to implanted dentin tubes filled with a white mineral trioxide aggregate.
(2002-03-01)