Buscar
Mostrando ítems 1-10 de 564
A strain gauge tactile sensor for finger-mounted applications
(Institute of Electrical and Electronics Engineers (IEEE), 2002-02-01)
This paper describes a strain gauge-based sensor used for measuring finger force. The theory, design, and sensor construction details are presented. It was constructed using metallic strain gauges and a carefully designed ...
A strain gauge tactile sensor for finger-mounted applications
(Institute of Electrical and Electronics Engineers (IEEE), 2002-02-01)
This paper describes a strain gauge-based sensor used for measuring finger force. The theory, design, and sensor construction details are presented. It was constructed using metallic strain gauges and a carefully designed ...
A strain gauge tactile sensor for finger-mounted applications
(Institute of Electrical and Electronics Engineers (IEEE), 2014)
Force Measurement with a Strain Gauge Subjected to Pure Bending in the Fluid–Wall Interaction of Open Water Channels
(2022)
An experimental method to measure forces of small magnitude with a strain gauge as a
force sensor in the fluid–wall interaction of open water channels is presented. Six uniaxial strain gauges were employed for this purpose, ...
Force Measurement with a Strain Gauge Subjected to Pure Bending in the Fluid–Wall Interaction of Open Water Channels
(2022)
An experimental method to measure forces of small magnitude with a strain gauge as a force sensor in the fluid–wall interaction of open water channels is presented. Six uniaxial strain gauges were employed for this purpose, ...
Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration
(Lippincott Williams & Wilkins, 2011-04-01)
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse ...
Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration
(Lippincott Williams & Wilkins, 2011-04-01)
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse ...
Projeto mecânico de um dinamômetro baseado em transdutores do tipo strain gauge para medição das componentes da força de usinagem no torneamento
(Universidade Federal do Rio Grande do NorteBrasilUFRNEngenharia MecânicaEngenharia Mecânica, 2021)