Search
Now showing items 1-7 of 7
Comparison of Single-Standing or Connected Implants on Stress Distribution in Bone of Mandibular Overdentures: A Two-Dimensional Finite Element Analysis
(Lippincott Williams & Wilkins, 2010-05-01)
This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models ...
Immediate loading of overdentures: systematic review
(2013-07-05)
Introduction: The goal of implant treatment is the formation of a direct bone-implant interface contact. Purpose: This study aimed to evaluate the possibilities of immediate loading treatment for edentulous patients ...
Comparing the efficacy of mandibular implant-retained overdentures and conventional dentures among elderly edentulous patients: satisfaction and quality of life
(Blackwell Publishing, 2007-12-01)
Objectives: the aim of this study was to compare the satisfaction and the quality of life in an elderly population using either mandibular conventional dentures or implant-retained overdentures.Materials and methods: A ...
Comparison of stress distribution between complete denture and implant-retained overdenture-2D FEA
(Blackwell Publishing, 2008-10-01)
The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional ...
A comparison of patient satisfaction between treatment with conventional complete dentures and overdentures in the elderly: a literature review
(Wiley-Blackwell, 2010-06-01)
Background:It has been stated that mandibular overdentures are more satisfactory than conventional dentures, but problems relating to the use of retrospective ratings, lack of control group and sequential provision of ...
Evaluation of Stress Patterns Produced by Implant-Retained Overdentures and Implant-Retained Fixed Partial Denture
(Lippincott Williams & Wilkins, 2011-11-01)
The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A ...
Clinical Viability for Immediate Loading of Dental Implants: Part II-Treatment Alternatives
(Lippincott Williams & Wilkins, 2009-11-01)
The treatment with implants aims to obtain a direct interface between bone and implant. The implant is kept load-free during 4 to 6 months in the 2-stage procedure, which is considered a requisite for osseointegration. ...