Buscar
Mostrando ítems 1-10 de 77
Seismic Response of Hybrid Systems with Metallic and Viscous Dampers
(2016-06-27)
Metallic dampers can enhance structural performance by reducing seismically induced lateral displacements, and by reducing inelastic behavior of beams and columns. Limiting story drift also indirectly allows for mitigation ...
Seismic Design of Multi-story Buildings with Metallic Structural Fuses
(2006-06-28)
Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for ...
Floor Response of SDOF Systems with Metallic Structural Fuses
(2004-06-26)
The floor demands of Single-Degree-of-Freedom (SDOF) systems designed or retrofitted with metallic structural fuses are studied in this article. Floor velocity and acceleration are obtained and comparisons are made between ...
Design of Floor Isolation Systems through Multi-Objective Criteria for the Seismic-Risk Performance
(2015)
This paper discusses a probabilistic framework for performance assessment and optimal design of floor isolation systems for the protection of acceleration sensitive contents. A multi-objective formulation is considered for ...
Linear isolation of stainless steel legged thin-walled tanks
(ELSEVIER SCI LTD, 2007)
Because of the booming wine industry in some seismic countries such as the US, Chile and Argentina, seismic protection of wine storage systems is of practical importance. In this study, the dynamic response of thin-walled ...
Analysis, testing, and implementation of seismic isolation of buildings in Chile
(WILEY, 2004)
This article Summarizes the work done by the authors in seismic isolation over the past six years in Chile. First, a general evaluation of the optimal values of the yield level of the isolation system is performed, focusing ...
Nonlinear FE model updating of seismic isolated bridge instrumented during the 2010 Mw 8.8 Maule-Chile Earthquake
(Elsevier, 2017)
In this paper, nonlinear finite element model updating (FEMU) is performed to study the prediction accuracy of a state-of-the-art
finite element (FE) model of a seismic isolated bridge (SIB). The seismic isolator model ...
Equivalent linear stochastic seismic analysis of cylindrical base-isolated liquid storage tanks
(Elsevier, 2013-04)
Seismic performance of cylindrical liquid storage tanks base-isolated by bilinear bearings is investigated. The paper displays a stochastic parametrical study in which three design parameters, namely isolation period, yield ...
Implementation of elastomeric seismic isolation in tall buildings considering axial-lateral coupling in the isolators
(National Information Centre of Earthquake Engineering, 2017)
Seismic isolation of high-rise buildings presents an opportunity but also a challenge to seismic isolation, a technique mostly used in the past in low and moderate-rise buildings. It turns out that under certain conditions ...
Seismic Response of Single-Degree-of-Freedom (SDOF) Structural Fuse Systems
(2004-06-26)
Passive energy dissipation (PED) devices have been implemented to enhance structural performance by reducing seismically induced structural damage. In this paper metallic dampers are defined to be structural fuses (SF) ...