Search
Now showing items 1-10 of 790
Caracterização do escoamento bifásico ar-água por meio de sensores ópticos
(Universidade do Vale do Rio dos Sinos, 2018-07-03)
This paper presents an air-water two-phase flow characterization in a small diameter tube of 2.6 mm internal diameter for plug and isolated flow, using four pairs of optical sensors: two of them consist in IR emitter whit ...
Caracterização do escoamento bifásico ar-água por meio de sensores ópticos
(Universidade do Vale do Rio dos Sinos, 2018-07-03)
This paper presents an air-water two-phase flow characterization in a small diameter tube of 2.6 mm internal diameter for plug and isolated flow, using four pairs of optical sensors: two of them consist in IR emitter whit ...
Desenvolvimento de um sensor óptico para medidas de fração de vazio de um minicanal
(Universidade do Vale do Rio dos Sinos, 2013-01-18)
This work presents the development of an experimental methodology for measuring
void fraction in an air-water two-phase flow, using optical sensor in a horizontal mini channel of 2.6 mm internal diameter. ...
Desenvolvimento de um sensor óptico para medidas de fração de vazio de um minicanal
(Universidade do Vale do Rio dos Sinos, 2013-01-18)
This work presents the development of an experimental methodology for measuring
void fraction in an air-water two-phase flow, using optical sensor in a horizontal mini channel of 2.6 mm internal diameter. ...
INTEGRATED RETENTION SPECTROPHOTOMETRIC DETECTION METHOD FOR THE DETERMINATION OF FORMALDEHYDE
(MARCEL DEKKER INC, 1992)
An integrated-sensor method for the determination of formaldehyde based on retention of the reaction product of the analyte with p-rosaniline and sulfite in a flow-cell packed with Dowex 1-X-8 anion exchange resin was ...
Integrated retention/spectrophotometric detection method for the determination of formaldehyde
(1992)
An integrated-sensor method for the determination of formaldehyde based on retention of the reaction product of the analyte with p-rosaniline and sulfite in a flow-cell packed with Dowex 1-X-8 anion exchange resin was ...
Flow-through photometric sensor for the determination of cadmium at the nanogram per millilitre level
(Marcel Dekker, Inc., 1993)
A sensor for the determination of cadmium based on retention of the CdI4" complex on a QAE Sephadex resin located in the flow-cell of a conventional photometric detector and on subsequent complex displacement reaction with ...
Flow-through photometric sensor for the determination of cadmium at toe nanogram per millilitre level
(1993)
A sensor for the determination of cadmium based on retention of the Cdl4″ complex on a QAE Sephadex resin located in the flow-cell of a conventional photometric detector and on subsequent complex displacement reaction with ...