Search
Now showing items 1-10 of 489
Analysis of the abutment-implant platform gap in internal hex dental implants
(Scientific Publishers of India, 2017)
Resistance to dynamic and static loading of the implant mounts on its respective implant
(2021-12-14)
Introduction: Implant restorations should endure a variable range of forces over a long period of time. Some commercial brands offer the implant together with an accessory called “implant mount” or “implant holder,” which ...
Necessidade de preenchimento dos espaços de peri-implantares em implantes imediatos
(Universidade Federal de Minas GeraisUFMG, 2015-04-24)
Immediate implants became a therapy quite popular today by shortening the treatment time, smaller number of surgeries and better patient compliance to a tooth to be extracted in the oral cavity. A gap between the implant ...
Influência do tipo de conexão protética, do platform-switching e do designe do implante no ambiente biomecânico de implantes imediatos com carga imediata
(Universidade Estadual Paulista (UNESP), 2014)
Análise experimental de copolímero na estabilidade primária de implantes osseointegráveis: avaliação microscópica em ratos
(Universidade Estadual Paulista (Unesp), 2006-03-14)
A estabilidade primária na instalação de implantes dentários é uma das determinantes principais no processo de osseointegração. Algumas situações clínicas impossibilitam o travamento adequado do implante. A diástase provocada ...
Características da superfície e da fenda implante-intermediário em sistemas de dois e um estágiosCharacteristics of implant surface and implant-abutment gap in two- and one-stage systems
(Faculdade De Odontologia De Bauru - USP, 2003)
The improvement of thin polymer film properties through plasma immersion ion implantation and deposition technique
(2001-12-01)
Thin polymer films were deposited from acetylene and argon mixtures by plasma immersion ion implantation and deposition. The effect of the pulse frequency, v, on molecular structure, optical gap, contact angle and hardness ...
The improvement of thin polymer film properties through plasma immersion ion implantation and deposition technique
(2001-12-01)
Thin polymer films were deposited from acetylene and argon mixtures by plasma immersion ion implantation and deposition. The effect of the pulse frequency, v, on molecular structure, optical gap, contact angle and hardness ...
Influência do tipo de conexão protética, do platform-switching e do designe do implante no ambiente biomecânico de implantes imediatos com carga imediata
(Universidade Estadual Paulista (Unesp), 2010-03-25)
O objetivo do presente trabalho de pesquisa foi avaliar a influencia do tipo de conexao protetica, do platform-switching, e do design do implante no ambiente biomec.nico de implantes imediatos com carga imediata. Para ...